ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (557)
  • 1985-1989  (287)
  • 1980-1984  (270)
  • 1940-1944
  • 1
    Publication Date: 2019-07-27
    Description: An experimental version of a thinned illuminated buried-channel 512 x 320 pixel CCD with reduced amplifier input capacitance has been produced which is characterized by lower readout noise. Changes made to the amplifier are discussed, and readout noise measurements obtained by several different techniques are presented. The single energetic electron response of the CCD in the electron-bombarded mode and the single 5.9 keV X-ray pulse height distribution are reported. Results are also given on the dark current versus temperature and the spatial frequency response as a function of signal level.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA, Washington Upper Atmosphere Res. Program; p 234-235
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-19
    Description: Results from an intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted at Wallops Island, VA, in July 1983. Instruments intercompared included a laser-induced fluorescence system and two chemiluminescence instruments. The intercomparisons were performed with ambient air at NO mixing ratios ranging from 10 to 60 pptv and NO-enriched ambient air at mixing ratios from 20 to 170 pptv. All instruments sampled from a common manifold. The techniques exhibited a high degree of correlation among themselves and with changes in the NO mixing ratio. Agreement among the three techniques was placed at approximately + or - 30 percent. Within this level of agreement, no artifacts or species interferences were identified.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 90; 12
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-18
    Description: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 21; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-19
    Description: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-28
    Description: The use of a plasma device, the Advanced Concepts Torus-I, for producing atoms and molecules to study spacecraft glow mechanisms is discussed. A biased metal plate, located in the plasma edge, is used to accelerate and neutralize plasma ions, thus generating a neutral beam with a flux approx. 5 x 10 to the 14th power/sq cm/sec at the end of a drift tube. Our initial experiments are to produce a 10 eV molecular and atomic nitrogen beam directed onto material targets. Photon emission in the spectral range 2000 to 9000 A from excited species formed on the target surface will be investigated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center 2d Workshop on Spacecraft Glow; p 202-211
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-28
    Description: The currently available methods for monitoring environmental microbial load call for the cultivation of microbes on laboratory media, a time- and material-consuming task that is potentially hazardous. Telemycology proposed in this communication is designed to eliminate the need for growing microbes, especially fungi, on board the spacecraft and to shift the bulk of the work-load to the ground-based Microbiology Laboratory. The system is based on the principle of trapping microbial propagules on a membrane filter, treating it with a microbe-enhancing reagent, and examining under a microscope down-linked to the central laboratory equipped with a synchronized televideo, telerobotics, and image banking system.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: SAE PAPER 891542
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-27
    Description: A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-27
    Description: The employment of area focal plane arrays (FPA) has made it possible to obtain second generation infrared imaging systems with high resolution and sensitivity. The Short Wavelength Infrared (SWIR) region (1-2.5 microns) is of importance for imaging objects at high temperature and under conditions of reflected sunlight. The present investigation is concerned with electrooptical characterization results for 32 x 32 SWIR detector arrays and FPAs which are suitable for use in a prototype imaging spectrometer. The employed detector material is Hg(1-x)Cd(x)Te grown by liquid phase epitaxy on a CdTe transparent substrate. Attention is given to details of processing, the design of the detector array, the multiplexer, the fabrication of the hybrid FPA, and aspects of performance.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Technical issues in infrared detectors and arrays; April 5, 6, 1983; Arlington, VA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...