Summary Various possibilities for the determination of trace impurities in high-purity iron by atomic spectrometry were investigated in detail. For Ba, Bi, Cd, Co, Cr, Cu, Mn, Ni, Pb, Ti and V, flame AAS, furnace AAS and ICP-OES were firstly evaluated in terms of their power of detection. Detection limits in the μg/g-range could be achieved by direct determination. For determination in the ng/g-range a removal of iron by a solvent extraction technique prior to the instrumental measurement was required. The power of detection of direct determination, and of combined procedures were compared with regard to routine applicability and a minimization of systematic errors.