ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 26 (1993), S. 733-735 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The properties of a new blue-colored Imaging Plate (IP), Fuji type UR-III, were examined with respect to spatial resolution and sensitivity to Cu Kα radiation. The spatial resolution of the new IP, estimated from the full width at half-maximum of the diffraction profile of a glutathione synthetase crystal, was 270 μm, smaller than that in a conventional IP, Fuji type BA (330 μm) and larger than that in an X-ray film, Kodak DEF-5 (210 μm). An estimation of the peak-to-background ratios of diffraction spots from a hen egg white lysozyme crystal shows that the new IP is at least 25 times more sensitive to Cu Kα radiation than the X-ray film. This new IP is a useful area detector to collect diffraction data from large-unit-cell crystals.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 25 (1992), S. 348-357 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A high-speed data-collection system for large-unit-cell crystals is presented, using the Fuji Imaging Plate as an X-ray detector and a rotating-anode generator as the X-ray source. It is an automatic data-acquisition system that requires almost no manual intervention. The quality of data collected on the system is discussed. Merging R values ranged from 0.04 to 0.05. Compared with a four-circle diffractometer, data reproducibility was better, isomorphous/anomalous Patterson maps were almost identical in quality and data from a small-molecule crystal, cytidine, were of almost the same quality. Protein structures were refinable using the data measured on the system, the final crystallographic R value of the 2.2 Å 3-isopropylmalatedehydrogenase structure being 0.185 and that of the 1.88 Å Flammulina veltipes agglutinin structure being 0.199.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 46 (1990), S. 263-270 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: The electron-density map of an Si crystal is drawn by the maximum-entropy method (MEM) with 30 structure factors which were determined very accurately on an absolute scale by the Pendellösung method [Saka & Kato (1986). Acta Cryst. A42, 469-478]. It is shown that the following three beneficial points arise from the use of the MEM for accurate structure analysis. Firstly, a precise electron-density map can be obtained; the existence of bonding electrons is clearly visible in the maximum-entropy map, even though no forbidden reflections are included in the analysis. The structure factors calculated from the maximum-entropy map for the 222 and the 442 forbidden reflections show good agreement with those measured by different experiments. The final R factor was 0.05% as a consequence of the high accuracy of the measured structure factors. Secondly, there is no need to seek a better structural model which could be a complicated and time-consuming process in accurate structure analysis. Thirdly, the resolution of the maximum-entropy map is much higher than that of the map drawn by conventional Fourier transformation. It is also found in the case of silicon that phase information is not absolutely necessary because exactly the same density-distribution map can be obtained without any phase information as the map drawn with all the phase information.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...