ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Plant breeding 109 (1992), S. 0 
    ISSN: 1439-0523
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: The hybridization barriers of interspecific lupin crosses were determined by histological investigations. The cross Lupinus hartwegii×L. mutabilis (both of American origin) revealed embryos in the cotyledonary stage as well as cellular endosperm. In the reciprocal combination, L. mutabilis×L. harwegii, embryo development stopped at the end of the globular stage, and simultaneously the coenocytic endosperm did no differentiate into the cellular state. In the combination L. luteus (European origin) ×L. hartwegii, embryo as well as endosperm development were initiated. Embryo development ended at any early globular stage. Twelve days after pollination the coenocytic endosperm had almost degenerated. With L. hartwegii as the female, no pollen germination could be observed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2538-2541 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Improved electrochemical techniques for the reproducible fabrication of sharp metallic tips are presented. Radii of curvature down to 10 nm make the tips particularly suitable for scanning tunneling microscopy (STM) and atomic force microscopy (AFM). Additionally, simple methods are developed for preparing AFM cantilevers. A new type of spherical probe suitable for long-range scanning force microscopy has been fabricated. The probes consist of nearly perfect spheres with adjustable radii between about 50 and several 100 nm deposited at the very tip of tiny probe holders. Both probe and probe holder may consist of any metal. First experimental investigations confirm that the spherical probes are particularly suitable for van der Waals and magnetic force microscopy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The use of a new Brillouin spectroscopic technique evidences the existence of internal stresses in white plasma assisted chemical vapor deposited diamond and allows a first assessment concerning their magnitude. The evaluation of the internal stresses is based on the pressure coefficients related to the longitudinal and transverse elastic constants. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 2613-2617 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A variable-temperature ultrahigh vacuum (UHV) scanning tunneling microscope (STM) was designed and tested. Design details and initial results are presented. The STM is directly attached to the cold face of a continuous flow cryostat which is mounted into a two-chamber UHV system. A significant advantage of this system in comparison to many others is, that samples can be cooled down to base temperature of 6.5 K within very short times of below 2 h. This feature not only increases the potential sample throughput, it also allows to cycle the sample temperature within the regime below 20 K without losing track of given sample locations. The instrument was tested by imaging Au layers on graphite. The vertical stability at low temperature was found to be below 3 pm. Images recorded at 6.5 K show crystalline Au islands and the Au(111)22×(square root of)3 reconstruction with atomic resolution. Using a resistive heater, the sample temperature was adjusted between 6.5 and 20 K. After an equilibration time of 15 min, the displacement due to the temperature change remained below 150 nm. Scanning tunneling spectroscopy on Au(111) grains resolves the Au(111) surface state. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 57 (1990), S. 2612-2614 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Quantitative image interpretation in magnetic force microscopy requires information about the geometric and magnetic configuration of the employed microprobe. If the magnetic microfield of a given sample is known in detail, a calibration of the probe is possible. Using the well-defined current-induced microfield of a nanolithographically structured conducting pattern, calibration measurements combined with model calculations provide an insight into the effective domain configuration of magnetic force microscopy probes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 56 (1990), S. 2578-2580 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Using a capacitively controlled force microscope we have imaged typical domain wall configurations like 90° closure structures and subdivided 180° wall segments in single-crystal iron whiskers. Differences in wall contrast between 90° and 180° domain walls are clearly observed. The effect of tip-to-sample distance on lateral resolution and wall contrast in magnetic force microscopy is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 57 (1990), S. 2351-2353 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Using a low-temperature scanning tunneling microscope spatial variations of the current-voltage characteristics have been investigated on NbSe2 single crystals employing PtIr and ferromagnetic Ni tips. At 4.2 K a clear superconducting energy gap is visible even when tunneling through the Ni tip. After field-induced transfer of the sample into the superconducting mixed state a complete Abrikosov flux lattice is imaged for both types of probes by recording the tunneling current at a fixed voltage within the superconducting gap. Comparison of the images obtained by the two probe materials clearly shows that no distortion of the flux lattice is produced by magnetostatic interactions between the ferromagnetic tip and the individual vortices. This provides the basis for future investigations of flux distributions in superconductors by magnetic force microscopy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 62 (1993), S. 1839-1841 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Electron holography is applied to the investigation of the leakage magnetic field produced by sharp ferromagnetic probes employed for magnetic force microscopy. Using the double exposure technique, interference fringes were obtained which show a good qualitative agreement with calculations based on a macroscopic dipole model for the sensor tips. Magnetic flux measurements are possible through the evaluation of the phase difference in the simulated map of the dipole field.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    World journal of microbiology and biotechnology 9 (1993), S. 229-232 
    ISSN: 1573-0972
    Keywords: Anaerobic ; bamboo ; support material ; wastewater treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract The changes in 2.5-cm thick bamboo rings during their use as a support material in an anaerobic reactor show that the wash out and degradation processes are largely completed within 6 months to a year. The dry mass of the bamboo used decreased more quickly in the first half of the year than during the second half and asymptotically approached a loss limit of approximately 15% (w/w). The decrease in substances contained in the bamboo during the 2-year experimental period led to reductions in wall thickness of the rings of 0.8 mm and in the absorbable pressure of 21%. Bamboo thus appears to be suitable for long-term use in an anaerobic reactor.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0630
    Keywords: 75.30 Pd ; 61.16 Di ; 75.25 tz ; 75.50 El
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract We report on recent developments in the field of STM performed with magnetic probes and samples. The choice of appropriate magnetic sensors and their in situ preparation will be described. We further focus on the information obtained in spin-polarized scanning tunneling microscopy (SPSTM) as well as on possible modes of operation for simultaneous acquisition of topographic and magnetic data. The prospects for SPSTM and related magnetic sensitive SXM techniques will be discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...