ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2)
  • Springer  (2)
  • 1995-1999  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 365 (1999), S. 592-596 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A digestion procedure was developed for the determination of selected elements (Al, Ba, Ca, Ce, Cd, Co, Cr, Cu, Fe, La, Mg, Ni, Sr, Pb, Zn) in sediments using XeF2. The use of XeF2 has some interesting features but this reagent should be handled only under dry gas which is a severe limitation of the methodology. In a first step the sediment sample (0.1 g) is dried (120 °C) and digested by XeF2 (1.5 g) in the vapor phase (190 °C; 9 × 106 Pa). Then the dry residue is dissolved in aqua regia and the solution digested at high pressure once again (aqua regia digestion). Subsequently the digested solution is diluted with sub-boiling distilled water and is ready for the analysis by ICP-MS. The sediment standard CRM 320 was analyzed to verify the procedure. A comparison of the results with those obtained by the normally used fluoric acid digestion showed that the recovery rates of each investigated element agreed within a confidence interval of 95%, except Cr. The recovery rate of Cr was lower for the XeF2 digestion than for the fluoric acid digestion by more than 5%. Further studies were focussed on the possible digestion of SiC by XeF2 as first step for the trace element determination. In the gaseous reaction products Si could be detected by ICP-MS which gives evidence to a decomposition of SiC. A digestion procedure for small Si samples (0.010 g) was developed. Detection limits (DL) determined for selected elements of analytical interest (Al, Ca, Cd, Cr, Co, Cu, Fe, Mg, Ni, Pb) were between 1 to 12 ng/g. For most of the elements this is an improvement in comparison to the HF vapor phase digestion. The verification of the method was carried out with GFAAS.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1999-11-26
    Print ISSN: 0937-0633
    Electronic ISSN: 1432-1130
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...