ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel  (140)
  • 1995-1999  (89)
  • 1980-1984  (45)
  • 1960-1964  (6)
Sammlung
  • Artikel  (140)
Erscheinungszeitraum
Jahr
Zeitschrift
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 965-970 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Various methods of metal ion production are presented with respect to multiply charged ion production. Depending on the ion source one or the other method is more commonly used. PIG ion sources for high charge states use mostly the sputtering technique for metal ions. ECR ion sources use oven techniques or direct evaporation by the plasma and also chemical compounds. Mevva ion sources use the vacuum arc and laser ion sources the laser power for evaporation and simultaneously multiple ionizing the metal atoms. Design details will be discussed in connection with these ion sources. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1344-1346 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The microwave plasma cathodes (MPC) dedicated to high-current ion sources are characterized by long lifetime with reactive gases and a compact structure. An Ishikawa-type MPC developed at GSI Darmstadt coupled with the CHORDIS ion source is presented. The electron current of the MPC is extracted from a dense plasma generated under electron-cyclotron-resonance condition. The axial magnetic field is produced by permanent magnets and ferromagnetic components. The 2.45 GHz microwave power (some tens of watts) is introduced into the plasma chamber via a coaxial line ended with a helical antenna. Experiments with argon and oxygen gas are presented and discussed. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1331-1333 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The pulsed magnetic field (PuMa)-electron cyclotron resonance (ECR) ion source uses a pulsed coil to improve the peak current by opening the magnetic bottle along the beam axis. After demonstration of the principle of the pulsed magnetic extraction, the ion source was tested with different gases. We received promising results from helium to krypton. The influence of the current in the pulsed coil on the analyzed ion current was measured. With increased current levels within the pulsed coil not only the pulse height of the PuMa pulse, but the pulse length can also be controlled. By using the pulsed coil the maximum of the charge state distribution can be shifted to higher charge states. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1368-1370 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: In cooperation with CEN-Grenoble we developed a high temperature oven for the production of beams from rare and expensive nickel isotopes (62Ni and 64Ni) with an electron cyclotron resonance (ECR) ion source Caprice-14 GHz. For the first time, nickel has been produced in this way. For an experiment at the Unilac we have provided a stable Ni9+ beam for 40 days with a mean intensity of 25 eμA. The nickel consumption was a few mg per hour and ten ovens have been used for that period. Surprising and promising results were obtained with this oven for the production of uranium beams by using UO2 samples. These results are compared with the "plasma heating'' method. Complementary investigations about the already studied "sputtering'' method are also presented. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 2578-2581 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The sinter density of small superconducting BSCCO samples (Bi2Sr2Can−1CunOy; n=1, 2, or 3; y about 7) was determined by hydrostatic weighing using a special technique to correct the mass data for penetration of immersion liquid. A discontinuity in the reevaporation curve permits one to distinguish between liquid, penetrated into the sample, and that adhering to the surface of the specimen. This allows one to calibrate by wiping away of excess liquid without fluid extraction out of sample pores. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 67 (1995), S. 200-202 
    ISSN: 1077-3118
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We report on measurements of the charge state distributions of ions formed in a vacuum arc plasma in a magnetic field. A vacuum arc ion source was used for plasma formation and ion beam extraction, and the charge state spectra were investigated using both magnetic and time-of-flight charge state diagnostics. We find that the charge states of all of the metal species investigated are significantly increased by a magnetic field of up to 6 kG. New high ion charge states are created, and the mean of the charge state distribution is increased by about 30% at 3.75 kG and 50% at 6 kG. The results are important fundamentally as well as being of relevance to vacuum arc ion source applications such as ion implantation and accelerator injection. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 17 (1984), S. 209-216 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 103 (1995), S. 3782-3787 
    ISSN: 1089-7690
    Quelle: AIP Digital Archive
    Thema: Physik , Chemie und Pharmazie
    Notizen: A method is presented that allows the calculation of phase diagrams (spinodal, binodal, and tie lines) of quaternary mixtures on the basis of the Gibbs energy of mixing ΔG. No derivatives of ΔG with respect to the composition variables are required. This method is particularly useful in cases where the composition dependence of ΔG is very complex, and no analytical representation of ΔG can be found. Phase diagrams have been calculated on the basis of the Flory–Huggins theory for mixtures of four polymers. Blends that phase separate because of very favorable interactions (negative interaction parameters) were of particular interest. In this case miscibility gaps can be located inside the tetrahedron composed of the Gibbs phase triangles of the four completely miscible ternary subsystems. For symmetrical mixtures of K components (identical chain lengths and interaction parameters) equations are presented that allow the calculation of K-phase and (K−1)-phase regions for any value of K. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 103 (1995), S. 3809-3819 
    ISSN: 1089-7690
    Quelle: AIP Digital Archive
    Thema: Physik , Chemie und Pharmazie
    Notizen: Using an effective (coarse-grained) thermodynamic potential describing the excess free energy of mixing of a polymer solution and fitting its parameters to measured critical point data, we obtain the "hump'' ε(τ) of this potential in the two-phase region (τ being the reduced distance from the critical temperature T of unmixing). For 30 different systems (varying the degree of polymerization r as well as choosing different polymer–solvent pairs) it is shown that the data are reasonably well represented by a power law, ε(τ)=εˆττζ. While mean field theory implies ζ=5/2 and scaling theory ζ=3ν+β≈2.22 (using Ising model exponents ν≈0.63,β≈0.325), the "effective'' exponent extracted from the data mostly falls in between these limits (ζeff≈2.4). Since the interfacial tension satisfies a similar power law, σ(τ)=σˆττμ (with μ=3/2 in mean field theory or μ=2ν≈1.26 in scaling theory), we also consider a relation between interfacial tension and free energy hump, σ(ε)=σˆεεcursive-phi. While mean-field theory implies cursive-phi=3/5 and scaling theory cursive-phi=2/(3+β/ν)≈0.57, the empirical exponent lies in the range 0.5(approximately-less-than)cursive-phieff(approximately-less-than)0.6. We present estimates of molecular weight dependencies of critical amplitude prefactors εˆτ,σˆτ,σˆε and of related quantities for many different systems. We also discuss whether the critical amplitude combination (εˆτ/Bˆτ)2/3/σˆ, where Bˆτ describes the coexistence curve {φcoex(2)−φcoex(1)=Bˆττβ} is universal. Contrary to some theoretical expectations, our data imply that this combination is not universal, and hence it cannot be used to predict interfacial tensions from equation of state data. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 4975-4980 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...