ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (2)
  • 1995-1999  (1)
  • 1980-1984  (1)
Collection
Keywords
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 3 (1981), S. 110-117 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The corrosion behaviour of orthopaedic metal implants was studied in an animal experiment in which 30 rabbits had stainless steel plates implanted after a varization osteotomy of the tibiae of their hind legs for one year. ESCA was used for the investigation of the surfaces of the inplants. The removed plates were covered by an easily destroyable 3-5 nm thick oxidic layer which contained Cr(III), Fe(II), Fe(III), Mo(VI) and Mo(IV), but no Ni. This passive layer (and possibly also the nearest metal layer below it) is strongly enriched in Cr. Additionally, corrosion experiments with radioactivated implants in Ringer's solution demonstrated that the passivation of the stainless steel is accompanied by marked selective solution of the steel constituents. The observed solubilities (Co 〉 Ni 〉 Fe 〉 Mo 〉 Cr) are inversely correlated with the abundance of the respective element in the passive layer. The trace element composition of the tissues was measured by instrumental neutron activation analysis. It turned out that the actual burdening of the tissues surrounding the implants by corrosion products is exhibited by strong enrichments of the elements Cr, Fe, Co, Ni and Mo relative to their normal concentrations. While Cr, Co, Ni and Mo are abundant in fairly constant ratios in the contact tissues, the excess of Fe is influenced by biological regulation mechanisms. The extent to which the distribution patterns of steel-specific elements in animal (and human) tissues can be explained by the dissolution of the steel during the passivation process is discussed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Macromolecular Theory and Simulations 5 (1996), S. 93-105 
    ISSN: 1022-1344
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Self-avoiding walks (SAWs) and random-flight walks (RFWs) of various lengths embedded on a simple cubic lattice have been computer generated inside cubes of varying side. If B is the side of the confining cube, we define the reduced cube side size B0 as B0 = (B - 1)/〈r2〉1/2, where 〈r2〉1/2 is the root-mean-square end-to-end distance of the non-confined chains. Dimensionless diagrams are then given of the Monte Carlo estimates for the dimensions, the entropy, and the compressibility parameter PV/(kT) of the confined chains as a function of B0. The comparative behaviour of the confined SAWs and RFWs is established, scaling properties are examined, and the Monte Carlo estimates compared with theory when such theory is available.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...