ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Institute of Physics (AIP)  (2)
  • Institute of Physics (IOP)
  • MDPI Publishing
  • 2000-2004  (2)
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 114 (2001), S. 3809-3816 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The behavior of tethered polymers on gel/gel adhesion is studied with the single-chain mean-field (SCMF) theory. It is shown that the gel surface structure, the gel/gel adhesion strength, the equilibrium gel/gel distance, and the detailed interface structures can be tailored by specifically designed tethered layers on gel surfaces. The SCMF theory allows to study the effect of various variables of tethered layers, such as the surface coverage, the attraction between polymers and gels, and the composition of block copolymers. These theoretical results provide guidelines for experimental designs of novel gel materials with tethered layers. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe a laser heated diamond anvil cell system at the GeoSoilEnviroCARS sector at the Advanced Photon Source. The system can be used for in situ x-ray measurements at simultaneously ultrahigh pressures (to 〉150 GPa) and ultrahigh temperatures (to 〉4000 K). Design goals of the laser heating system include generation of a large heating volume compared to the x-ray beam size, minimization of the sample temperature gradients both radially and axially in the diamond anvil cell, and maximization of heating stability. The system is based on double-sided laser heating technique and consists of two Nd:YLF lasers with one operating in TEM00 mode and the other in TEM01* mode, optics to heat the sample from both sides, and two spectroradiometric systems for temperature measurements on both sides. When combined with an x-ray microbeam (3–10 μm) technique, a temperature variation of less than 50 K can be achieved within an x-ray sampled region for longer than 10 min. The system has been used to obtain in situ structural data and high temperature equations of state on metals, oxides, and silicates to 3500 K and 160 GPa. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...