ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2016-03-01
    Description: Interdigitated thin film humidity sensors have been prepared using organic/inorganic nanocomposites of poly(diphenylamine sulfonic acid) (PSDA), 3-mercaptopropyltrimethoxysilane (MPTMS), and nano-ZnO. Humidity sensing properties of the sensors, regarding the effect of nano-ZnO addition and the applied alternating current frequency, were studied by impedance measurements in the frequency range of 100 Hz–1 kHz. It was found that the sensing properties of the ZnO based nanocomposite sensors had better properties than those of the PSDA-MPTMS based composite due to contribution of the nanomaterial. Good sensitivity (about three orders’ magnitude change in impedance), linear response, rapid response (90 s) and recovery (60 s), and low hysteresis within 4% as well as good repeatability and stability in the range from 12% to 95% RH were obtained.
    Print ISSN: 1687-725X
    Electronic ISSN: 1687-7268
    Topics: Electrical Engineering, Measurement and Control Technology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2016-02-18
    Description: Box-Behnken design was applied to optimize high performance liquid chromatography (HPLC) conditions for the simultaneous determination of potassium sorbate, sodium benzoate, carmoisine, allura red, ponceau 4R, and caffeine in commercial soft drinks. The experimental variables chosen were pH (6.0–7.0), flow rate (1.0–1.4 mL/min), and mobile phase ratio (85–95% acetate buffer). Resolution values of all peak pairs were used as a response. Stationary phase was Inertsil OctaDecylSilane- (ODS-) 3V reverse phase column (250 × 4.6 mm, 5 μm) dimensions. The detection was performed at 230 nm. Optimal values were found 6.0 pH, 1.0 mL/min flow rate, and 95% mobile phase ratio for the method which was validated by calculating the linearity (), accuracy (recoveries ≥ 95.75%), precision (intraday variation ≤ 1.923%, interday variation ≤ 1.950%), limits of detection (LODs), and limits of quantification (LOQs) parameters. LODs and LOQs for analytes were in the range of 0.10–0.19 μg/mL and 0.33–0.63 μg/mL, respectively. The proposed method was applied successfully for the simultaneous determination of the mixtures of five food additives and caffeine in soft drinks.
    Print ISSN: 1687-8760
    Electronic ISSN: 1687-8779
    Topics: Chemistry and Pharmacology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2016-01-01
    Description: Interdigitated thin film humidity sensors have been prepared using organic/inorganic nanocomposites of poly(diphenylamine sulfonic acid) (PSDA), 3-mercaptopropyltrimethoxysilane (MPTMS), and nano-ZnO. Humidity sensing properties of the sensors, regarding the effect of nano-ZnO addition and the applied alternating current frequency, were studied by impedance measurements in the frequency range of 100 Hz–1 kHz. It was found that the sensing properties of the ZnO based nanocomposite sensors had better properties than those of the PSDA-MPTMS based composite due to contribution of the nanomaterial. Good sensitivity (about three orders’ magnitude change in impedance), linear response, rapid response (90 s) and recovery (60 s), and low hysteresis within 4% as well as good repeatability and stability in the range from 12% to 95% RH were obtained.
    Print ISSN: 1687-725X
    Electronic ISSN: 1687-7268
    Topics: Electrical Engineering, Measurement and Control Technology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2017-01-01
    Description: The substantial of mineral ingredients in honey may symbolize the existence of elements in the plants and soil of the vicinity wherein the honey was taken. The aim of this study was to detect the levels of 13 elements (Potassium (K), Sodium (Na), Calcium (Ca), Iron (Fe), Zinc (Zn), Cadmium (Cd), Copper (Cu), Manganese (Mn), Lead (Pb), Nickel (Ni), Chromium (Cr), Aluminum (Al), and Selenium (Se)) in unifloral and multifloral honey samples from south and east regions of Turkey. Survey of 71 honey samples from seven different herbal origins, picked up from the south and east region of Turkey, was carried out to determine their mineral contents during 2015-2016. The mineral contents were analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The most abundant minerals were K, Na, and Ca ranging within 1.18–268 ppm, 0.57–13.1 ppm, and 0.77–4.5 ppm, respectively. Zn and Cu were the most abundant trace element while Pb, Cd, Ni, and Cr were the lowest heavy metals in the honey samples surveyed, with regard to the concentrations of heavy metals such as Zn, Cu, Pb, Cd, Ni, and Cr suggested and influence of the botanical origin of element composition. Geochemical and geographical differences are probably related to the variations of the chemical components of honey samples.
    Print ISSN: 1687-8760
    Electronic ISSN: 1687-8779
    Topics: Chemistry and Pharmacology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2018-01-01
    Description: Maternal breast milk is a unique biological matrix that contains essential micronutrients. Potentially heavy metals may also affect infants’ health and growth through maternal breast milk. The purpose of this study was to determine and compare the essential elements and heavy metals of maternal breast milk of nursery mothers residing in Şanlıurfa province, Turkey. Maternal breast milk concentrations of sodium, magnesium, phosphorus, potassium, calcium, iron, copper, zinc, arsenic, and lead were analyzed in a random sample of the first time in urban and suburban nursery Turkish mothers (n: 42). Eight essential elements and two heavy metals were analyzed using ICP-MS after microwave digestion. For bivariate analyses of variables, we use nonparametric Spearman’s correlation coefficient test. The mean concentrations of essential elements and heavy metals were as follows: sodium 330 ± 417 mg/L, magnesium 32.6 ± 15.5 mg/L, phosphorus 156 ± 46.2 mg/L, potassium 488 ± 146 mg/L, calcium 193 ± 53.2 mg/L, iron 1.65 ± 1.43 mg/L, copper 0.54 ± 0.46 mg/L, zinc 2.89 ± 3.23 mg/L, arsenic 〈 1 μg/L, and lead 〈 1 μg/L. Concentrations of heavy metals in maternal breast milk may have the important implication that it is not affected by environmental pollution in this province. This study provides reliable information about maternal breast milk concentrations of nursery mothers residing in Şanlıurfa, Turkey, and also compares the relations between essential elements and socioeconomic conditions, residing areas, and using copper equipment for food preparation of which some have not previously been reported.
    Print ISSN: 1687-8760
    Electronic ISSN: 1687-8779
    Topics: Chemistry and Pharmacology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2016-01-01
    Description: Box-Behnken design was applied to optimize high performance liquid chromatography (HPLC) conditions for the simultaneous determination of potassium sorbate, sodium benzoate, carmoisine, allura red, ponceau 4R, and caffeine in commercial soft drinks. The experimental variables chosen were pH (6.0–7.0), flow rate (1.0–1.4 mL/min), and mobile phase ratio (85–95% acetate buffer). Resolution values of all peak pairs were used as a response. Stationary phase was Inertsil OctaDecylSilane- (ODS-) 3V reverse phase column (250 × 4.6 mm, 5 μm) dimensions. The detection was performed at 230 nm. Optimal values were found 6.0 pH, 1.0 mL/min flow rate, and 95% mobile phase ratio for the method which was validated by calculating the linearity (r2〉0.9962), accuracy (recoveries ≥ 95.75%), precision (intraday variation ≤ 1.923%, interday variation ≤ 1.950%), limits of detection (LODs), and limits of quantification (LOQs) parameters. LODs and LOQs for analytes were in the range of 0.10–0.19 μg/mL and 0.33–0.63 μg/mL, respectively. The proposed method was applied successfully for the simultaneous determination of the mixtures of five food additives and caffeine in soft drinks.
    Print ISSN: 1687-8760
    Electronic ISSN: 1687-8779
    Topics: Chemistry and Pharmacology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2016-01-01
    Description: A new procedure for separation and preconcentration of trace amounts of Cu(II), Ni(II), Fe(III), Zn(II), Cr(III), Cd(II), and Pb(II) in fish samples was proposed. The procedure is based on the adsorption of these metal ions on the column of Amberlite XAD-7 as congo red complexes prior to their determination by flame atomic absorption spectrometry (FAAS). Several factors that can affect the sorption and elution efficiency of the metal ions were investigated and optimized. The sorption was quantitative in the pH range of 6.0–9.0 for Cu(II) and Ni(II), 5.5–8.0 for Fe(III), 6.0–8.5 for Zn(II) and Cd(II), and 7.0–8.5 for Cr(III) and Pb(II). The optimum pH for simultaneous retention was 7.5. The sorption capacity of the resin was found to be 0.89, 0.72, 0.82, 0.61, 0.53, 0.84, and 0.78 mg/g for Cu(II), Ni(II), Fe(III), Zn(II), Cr(III), Cd(II), and Pb(II), respectively. The precision of the method was evaluated as the relative standard deviation obtained by analyzing a series of six replicates and below 6% for all seven elements. The validation of the method was performed by the analysis of certified reference materials. The proposed method was successfully applied to separation/preconcentration and determination of these metals in fish samples.
    Print ISSN: 2090-9063
    Electronic ISSN: 2090-9071
    Topics: Chemistry and Pharmacology
    Published by Hindawi
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...