ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Institute of Physics (AIP)  (2)
  • Oxford University Press
  • 1995-1999  (2)
  • 1998  (2)
Collection
Publisher
Years
  • 1995-1999  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 83 (1998), S. 4106-4110 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The growth of a displacement field in single crystal silicon resulting from high dose hydrogen implantation and subsequent heat treatments has been investigated by MeV 4He+ Rutherford backscattering in channeling conditions, double crystal x-ray diffraction, and transmission electron microscopy. The results obtained in samples annealed for various times in the temperature range 220–350 °C have been explained in terms of a kinetic model which assumes the formation of clusters of hydrogen molecules. The growth of the displacement field is thermally activated with an activation energy of 0.50±0.05 eV, suggesting that the limiting process could be the release of hydrogen atoms bounded to defects created by ion implantation. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 84 (1998), S. 4802-4808 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The modifications induced in single-crystal silicon by implanted helium have been investigated by ion beam techniques. The damage has been detected by 2 MeV 4He+ backscattering in channeling conditions and the helium in-depth distribution by 7 and 8 MeV 15N++ elastic recoil scattering. The samples prepared by implanting 2×1016 cm−2 helium ions at 20 keV in silicon wafers held either at 77 K (LNT sample) or at 300 K (RT sample) have been heat treated for 2 h in the 100–800 °C temperature range. In the as-implanted LNT sample the damage maximum is at 130±20 nm and shifts in-depth to 180±10 nm after annealing at 200 °C, in the as-implanted RT sample, the damage maximum is already located at 180±10 nm. In the 250–500 °C temperature range, the LNT and RT samples follow the same annealing path with only slight differences in the temperature values; in both cases, the dechanneling signal increases and reaches a maximum value of nonregistered silicon atoms of 2.2–2.5×1022 at/cm3. In the same temperature range, the helium signal becomes narrower, builds up in a region centered on 220±20 nm and no appreciable loss of helium can be detected. The growth of the damage is consistent with the creation of cracks and a etherogenous distribution of bubbles filled with high pressure helium which stress the lattice; for the channeling Rutherford backscattering technique, their action is similar to silicon interstitials. At temperatures above 500 °C, helium is released from the samples; this process is associated with a decrease of the damage and the formation and increase in size of voids. At 900 °C empty voids with a diameter around 20 nm are found. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...