ISSN:
0021-9304
Schlagwort(e):
Chemistry
;
Polymer and Materials Science
Quelle:
Wiley InterScience Backfile Collection 1832-2000
Thema:
Medizin
,
Technik allgemein
Notizen:
PMMA beam specimens were tested in four-point bending to determine if the bending strength of acrylic bone cement, as used in posterior spinal fusion, could be improved by metal-wire reinforcement. The result showed that the load-carrying capacities of 1- and 0.5-mm diam stainless-steel-wire-reinforced PMMA specimens in bending were significantly higher than similar unreinforced normal PMMA samples. On an average, steel reinforcement comprising approximately 1% of the cross-sectional area of the PMMA specimens caused a 15% increase in bending strength. Even after the cement fractured, the reinforcing wires still sustained an appreciable amount of bending moment, thus preventing catastrophic failure of cement alone.
Zusätzliches Material:
8 Ill.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1002/jbm.820130309
Permalink