ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die übliche Methode der papierchromatographischen Trennung und Bestimmung von kondensierten Phosphaten ist in ihrer Anwendung dadurch eingeschränkt, daß zu ihrer Durchführung zweckmäßig Konzentrationen von 1000–5000 mg je Phosphat in 1 l erforderlich sind. Bei Proben, die z.B. im Bereich der Wasserchemie, der Lebensmittelchemie oder der biologischen Chemie in Frage kommen, liegen die gesuchten Phosphatgehalte meist wesentlich niedriger. Eine Konzentrierung durch Eindampfen würde u. a. die Zustandsform der Phosphate infolge Hydrolyse verändern. Zur Bestimmung der verschiedenen Phosphate in diesen Bereichen eignet sich die Anionenaustauscher-Chromatographie. Sie ermöglicht es, ionogen gelöste Phosphate abzutrennen und Hinweise auf die Verteilung von nicht ionogen gelösten anorganischen und organischen Phosphaten zu erhalten. Bis in den Konzentrationsbereich von weniger als 1 mg Gesamt-P2O5 im Liter können ionogen gelöste kondenierte Phosphate getrennt und bestimmt werden. In den angeführten Beispielen wurden in phosphatbehandeltem Trinkwasser, in Flußwasser und in Abwasser bis zu 7 verschiedene Zustandsformen von Phosphaten nebeneinander bestimmt: Unter den beschriebenen Arbeitsbedingungen ungelöste Phosphate, nicht ionogen gelöste hochkondensierte anorganische Phosphate und organische Phosphate, und ionogen gelöste Verbindungen (getrennt in Mono-, Di-, Tri-, Trimeta- und hochkondensierte Phosphate).
    Notes: Summary The usual method of paper-chromatographic separation and determination of condensed phosphates is limited in its application, because it requires concentrations of 1000 to 5000 mg in 1 l for each phosphate. For samples which are involved e.g. in the field of water chemistry, food chemistry or biological chemistry, the desired phosphate contents are mostly far lower. A concentration by evaporating would change the state of the phosphates by hydrolysis. Anion-exchange chromatography is suitable for the determination of different phosphates in these fields. It permits the separation of ionically dissolved phosphates and allows to obtain information about the distribution of inorganic and organic phosphates not ionically dissolved. Ionically dissolved condensed phosphates can be separated and determined up to a concentration of less than 1 mg of total P2O5 per liter. In the examples mentioned above up to 7 different states of phosphates were individually determined in drinking water treated with phosphate, in river water and in waste water: phosphates undissolved under the conditions described, not ionically dissolved high condensed inorganic phosphates and organic phosphates, and ionically dissolved compounds (separated in mono-, di-, tri-, trimeta- and highcondensed phosphates).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 277 (1954), S. 249-257 
    ISSN: 0044-2313
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Aus Niobdioxyd, Niobmetall und Kohlenstoff werden Niobcarbidpräparate mit Zusammensetzungen zwischen NbC1,00 und Nb dargestellt und röntgenographisch auf die vorliegenden Phasenverhältnisse untersucht. Es bestehen 3 Phasen im System Nb—C: Die Monocarbidphase, von NbC1,00 bis NbC0,72 homogen, mit Steinsalzgitter, die Subcarbidphase, von NbC0,50 bis NbC0,35 homogen, mit hexagonal dichtester Kugelpackung der Niobatome, und die Niobmetallphase mit einem Lösungsvermögen für Kohlenstoff bis zur Zusammensetzung NbC0,02. Diese Befunde beziehen sich auf eine Darstellungstemperatur der Präparate von 1600-1700° C.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...