ISSN:
1573-1472
Source:
Springer Online Journal Archives 1860-2000
Topics:
Geosciences
,
Physics
Notes:
Abstract Turbulence data for the International Turbulence Comparison Experiment (ITCE) held at Conargo, N.S.W. (35° 18′ S., 145° 10′ E.) during October, 1976 are analysed. The standard deviation % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaiikaiqado% hagaqbamaaCaaaleqabaGaaGOmaaaakiaacMcadaahaaWcbeqaaiaa% igdacaGGVaGaaGOmaaaaaaa!3B93!\[(s'^2 )^{1/2} \] and covariance % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaWaa0aaaeaace% WG3bGbauaaceWGZbGbauaaaaaaaa!3809!\[\overline {w's'} \] measured by a number of instruments and instrument arrays have been compared to assess their field performance and calibration accuracy. Satisfactory agreement, i.e. typically 5% for % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaiikamaana% aabaGabm4CayaafaWaaWbaaSqabeaacaaIYaaaaaaakiaacMcadaah% aaWcbeqaaiaaigdacaGGVaGaaGOmaaaaaaa!3BA4!\[(\overline {s'^2 } )^{1/2} \] (except in humidity) and of the order of 20% for % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaiikaiqado% hagaqbamaaCaaaleqabaGaaGOmaaaakiaacMcadaahaaWcbeqaaiaa% igdacaGGVaGaaGOmaaaaaaa!3B93!\[(s'^2 )^{1/2} \], was achieved, but only after consideration of: (1) Instrumental response at high frequencies. (2) Flow distortion induced by instruments and supporting structures. (3) Spatial separation of instruments used for covariance measurements. (4) Statistical errors associated with single point measurements over a finite averaging time, and with lateral separation of two sensor arrays being compared.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF00121667
Permalink