ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 39 (1990), S. 2419-2441 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Dielectric techniques have been implemented to study aqueous colloidal suspensions. A four electrode cell was used in two configurations; the first, a sweep of frequencies using a sequence of standard single frequency null-balance measurements, and the second relying on the dielectric response to a Fourier synthesized pseudo random white noise (FSPN) with measurements performed using correlation techniques in the time domain. Single frequency measurements, which take on the order of 5-10 min per spectrum, were performed on polymer latex standards of varying size, latex concentration, and electrolyte concentration and were extended from 0.02 to over 500 kHz. It was found that the central relaxation frequency fc was inversely propotional to the square of the particle size, consistent with previous experimental results. Experiments were performed at different particle concentration and ionic strengths, and the magnitude and breadth of the dielectric dispersion was analyzed in terms of current theories. The distribution of relaxation times was found to be in general qualitative agreement with those predicted by some existing theories. The results indicate that a wide range of conditions exist in terms of latex concentration and ionic environment where the rapid and accurate measurement of polymer latex particle size and size distribution is feasible. FSPN measurements, which take on the order of seconds, were shown to be accurate over a moderate frequency range for model electrical network studies but were only partially successful for aqueous suspensions of latex because of high frequency limitations in the electronics. Experimental details and difficulties concerning the application of this technique are discussed.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...