ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 2019
    Description: The present research develops a systematic application of a selected family of 11 well-known design storms, all of them obtained from the same rainfall data sample. Some of them are fully consistent with the intensity–duration–frequency (IDF) curves, while others are built according to typical observed patterns in the historical rainfall series. The employed data series consists on a high-resolution rainfall time series in Valencia (Spain), covering the period from 1990 to 2012. The goal of the research is the systematic comparison of these design storms, paying special attention to some relevant quantitative properties, as the maximum rainfall intensity, the total cumulative rainfall depth or the temporal pattern characterising the synthetic storm. For comparison purposes, storm duration was set to 1 h and return period equal to 25 years in all cases. The comparison is enhanced by using each of the design storms as rainfall input to a calibrated urban hydrology rainfall–runoff model, yielding to a family of hydrographs for a given neighbourhood of the city of Valencia (Spain). The discussion and conclusions derived from the present research refer to both, the comparison between design storms and the comparison of resulting hydrographs after the application of the mentioned rainfall–runoff model. Seven of the tested design storms yielded to similar overall performance, showing negligible differences in practice. Among them, only Average Variability Method (AVM) and Two Parameter Gamma function (G2P) incorporate in their definition a temporal pattern inferred from empirical patterns identified in the historical rainfall data used herein. The remaining four design storms lead to more significant discrepancies attending both to the rainfall itself and to the resulting hydrograph. Such differences are ~8% concerning estimated discharges.
    Electronic ISSN: 2073-4441
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Published by MDPI
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...