ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 2017-08-21
    Description: In 1995, we participated in a number of WOCE Hydrographic Program cruises in the Indian Ocean as part of the Joint Global Ocean Flux Study (JGOFS) CO2 Survey sponsored by the Department of Energy (DOE). Two titration systems were used throughout this study to determine the pH, total alkalinity (TA) and total inorganic carbon dioxide (TCO2) of the samples collected during these cruises. The performance of these systems was monitored by making closed cell titration measurements on Certified Reference Materials (CRMs). A total of 962 titrations were made on six batches of CRMs during the cruises. The reproducibility calculated from these titrations was ±0.007 in pH, ±4.2 μmol kg−1 in TA, and ±4.1 μmol kg−1 in TCO2. The at-sea measurements on the CRMs were in reasonable agreement with laboratory measurements made on the same batches. These results demonstrate that the CRMs can be used as a reference standard for TA and to monitor the performance of titration systems at sea. Measurements made on the various legs of the cruise agreed to within 6 μmol kg−1 at the 15 crossover points. The overall mean and standard deviation of the differences at all the crossovers are 2.1±2.1 μmol kg−1. These crossover results are quite consistent with the overall reproducibility of the CRM analyses for TA (±4 μmol kg−1) over the duration of the entire survey. The TA results for the Indian Ocean cruises provide a reliable data set that when combined with TCO2 data can completely characterize the carbonate system.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2017-08-18
    Description: Two single-operator multiparameter metabolic analyzers (SOMMA)-coulometry systems (I and II) for total carbon dioxide (TCO2) were placed on board the R/V Knorr for the US component of the Indian Ocean CO2 Survey in conjunction with the World Ocean Circulation Experiment-WOCE Hydrographic Program (WHP). The systems were used by six different measurement groups on 10 WHP Cruises beginning in December 1994 and ending in January 1996. A total of 18,828 individual samples were analyzed for TCO2 during the survey. This paper assesses the analytical quality of these data and the effect of several key factors on instrument performance. Data quality is assessed from the accuracy and precision of certified reference material (CRM) analyses from three different CRM batches. The precision of the method was 1.2 μmol/kg. The mean and standard deviation of the differences between the known TCO2 for the CRM (certified value) and the CRM TCO2 determined by SOMMA-coulometry were −0.91±0.58 (n=470) and −1.01±0.44 (n=513) μmol/kg for systems I and II, respectively, representing an accuracy of 0.05% for both systems. Measurements of TCO2 made on 12 crossover stations during the survey agreed to within 3 μmol/kg with an overall mean and standard deviation of the differences of −0.78±1.74 μmol/kg (n=600). The crossover results are therefore consistent with the precision of the CRM analyses. After 14 months of nearly continuous use, the accurate and the virtually identical performance statistics for the two systems indicate that the cooperative survey effort was extraordinarily successful and will yield a high quality data set capable of fulfilling the objectives of the survey.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...