Publication Date:
2014-06-26
Description:
We compare different strategies for minimizing the effects of telescope vibrations to the differential piston (optical pathway difference) for the Near-InfraRed/Visible Adaptive Camera and INterferometer for Astronomy (LINC-NIRVANA) at the Large Binocular Telescope (LBT) using an accelerometer feedforward compensation approach. We summarize, why this technology is important for LINC-NIRVANA, and also for future telescopes and already existing instruments. The main objective is outlining a solution for the estimation problem in general and its specifics at the LBT. Emphasis is put on realistic evaluation of the used algorithms in the laboratory, such that predictions for the expected performance at the LBT can be made. Model-based estimation and broad-band filtering techniques can be used to solve the estimation task, and the differences are discussed. Simulation results and measurements are shown to motivate our choice of the estimation algorithm for LINC-NIRVANA. The laboratory setup is aimed at imitating the vibration behaviour at the LBT in general, and the M2 as main contributor in particular. For our measurements, we introduce a disturbance time series which has a frequency spectrum comparable to what can be measured at the LBT on a typical night. The controllers’ ability to suppress vibrations in the critical frequency range of 8–60 Hz is demonstrated. The experimental results are promising, indicating the ability to suppress differential piston induced by telescope vibrations by a factor of about 5 (rms), which is significantly better than any currently commissioned system.
Print ISSN:
0035-8711
Electronic ISSN:
1365-2966
Topics:
Physics
Permalink