ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] THE International Ultraviolet Explorer (IUE) was launched successfully on 26 January 1978, from Cape Canaveral, Florida. The satellite was developed to provide a general facility for observing ultraviolet (UV) spectra of astronomical sources over the wavelength range from about 1,150 Å to ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 23 (1984), S. 213-222 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Summary Tumour cords have been examined quantitatively in two rat hepatomas, 3924A and H-4-II-E, that differ in their radiobiological oxygenation status (oxygen enhancement ratio for growth delay [tumour clamped: tumor ‘in air’] was 1.35 for 3924A and only 1.08 for H-4-II-E). The average thickness of tumour cords in 3924A was 118 µm and only 69 µm in H-4-II-E. The migration rates across the cords of the two tumours were approximately the same (1.7 and 1.4 µm ⋅ h−1) but for any given distance from the subtending blood vessel, the proportion of histologically-dead cells within the cord was always higher for H-4-II-E. Volume for volume, H-4-II-E contained four times as much vascular space as 3924A but it is suggested that the poorquality of this vasculature in H-4-II-E contributed to its relative radioresistance.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Radiation and environmental biophysics 24 (1985), S. 211-218 
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Summary The gross growth rate, histology, cellular kinetics, andin situ radiobiological response have been measured for three murine, keratinising squamous cell carcinomas that differed in their degree of differentiation. Growth rate was fastest in the least-differentiated tumour, slowest in the best-differentiated. However, the kinetics of the compartment of undifferentiated cells that are likely to be radiotherapeutically important, were the same for the three lines. There was no correlation between degree of differentiation and intrinsic or apparent radiosensitivity as measured by the growth delay assay. The radiobiologically best-oxygenated tumour was that which had the largest stromal component and this was not the best-differentiated tumour.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 5 (1990), S. 395-398 
    ISSN: 1435-604X
    Keywords: Photodynamic therapy ; Lasers ; Light dosimetry ; Skeletal muscle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract For precise light dosimetry in photodynamic therapy (PDT), the light penetration characteristics of the tissue concerned need to be assessed. Several attenuation coefficients have so far been measured using 633 nm wavelength red light and human tissue obtained from autopsy or surgery. However, the validity of such ex vivo derived values remains uncertain, and hence is evaluated further in this study. Using a rat thigh muscle model, the tissue transmittance of 633 nm red light was compared between in vivo and ex vivo. Transmittance (in vivo) following preliminary injection of 40 mg kg−1 haematoporphyrin derivative (HPD) was also measured in muscle and liver. The effective attenuation coefficient (⌆eff) ex vivo in muscle was 0.98±0.06 mm−1 and in vivo 0.97 ± 0.05 mm−1. Values agreed within experimental error indicating that in this tissue, changes from in vivo to post-mortem produced no alteration in optical penetration at 633 nm. Preliminary injection of HPD did not influence the penetration depth in muscle although significant changes were observed in an organ of high porphyrin avidity, the liver (0.68±0.08 mm vs 0.40±0.08 mm with HPD). Until techniques for in vivo measurements of light attenuation coefficient become available, the use of ex vivo derived values with 633 nm wavelength light would seem appropriate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 11 (1996), S. 155-161 
    ISSN: 1435-604X
    Keywords: Photodynamic therapy ; Interstitial ; Dunning R3327 prostate tumour ; Threshold light dose ; Cylindrical diffuser ; Diffusion theory
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract Interstitial photodynamic therapy (PDT) could be an alternative radical treatment for prostate cancer. The ability to predict the depth of necrosis is necessary for light treatment planning using multiple optical fibres. The extent of PDT necrosis was studied in subcutaneously implanted R3327-AT6 Dunning prostate tumours which had similar optical characteristics to human prostate. Tumour-bearing subjects were given 20 mg kg−1 Haematoporphyrin esters (HPE) and irradiated 24 h later with 630 nm laser light. Five subjects per group were treated with increasing light doses (50–450 J cm−1) delivered interstitially via a single 2 cm long cylindrical diffuser. After 450 J cm−1 of irradiation, 4.3±0.8 cm3 [standard error of the mean (s.e.m.)] of tumour tissue was necrosed to a depth of 10.5±0.8 mm around the diffuser. There was an approximately linear correlation between the volume of PDT necrosis around the fibre and prescribed light dose. The mean threshold light dose for PDT effect was 18±2 J cm−2. In this tumour with a mean photosensitizer concentration of 16±1.5μg g−1, low light doses produced tumour necrosis. PDT using multiple diffusers could destroy a relatively large tumour volume and the ‘diffusion theory’ model reliably predicted the depth of necrosis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1435-604X
    Keywords: Photodynamic therapy ; Haematoporphyrin derivative ; In vivo ; Laser ; Light source ; Murine tumour
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract The performance of a low cost, table-top/portable light source was tested against an argon ion pumped dye laser for in vivo photodynamic therapy (PDT). The prototype delivers up to 1 W via a 4 mm flexible lightguide within a 30 nm bandwidth centred at any wavelength from 300 nm to 1200 nm at fluence rates of up to 8 W cm−2. An in situ bioassay using regrowth delay of tumour T50/80 was used to quantify the relative efficacy of the prototype with a laser. The tumours were sensitized with haematoporphyrin derivative (HpD) and externally irradiated. There was no significant difference in the response of the tumour to treatment between the two light sources (p = 0.69). Mean growth delays ranged from 2 days (light dose 10 J cm−2) to 20 days (light dose 100 J cm−2). The estimate for the difference in means (laser minus prototype growth delay) was only 0.66 days and was not statistically significant. This in vivo study demonstrates that the prototype is equivalent to a laser in PDT effect. The device has low capital/running cost, is simple to use and is one of the most powerful, spectrally efficient non-laser PDT sources available.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1435-604X
    Keywords: Photodynamic therapy ; Non-laser light source ; 5-Aminolaevulinic acid ; Non-melanoma skin cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract The efficacy of a prototype non-laser light source for photodynamic therapy was assessed in clinical practice in the treatment of Bowen's disease and actinic keratoses. The light source, incorporating a 300 W short arc plasma discharge, was adjusted by appropriate filters to produce a bandwidth of 630±15 nm. Topical 5-aminolaevulinic acid was applied 4 h before irradiation to permit production within the lesion of the active photosensitizer, protoporphyrin IX. Individual lesions received 94–156 J cm−2. Twenty lesions of Bowen's disease and four actinic keratoses were treated in 12 patients. Patients were reviewed at monthly intervals and treatment repeated if residual disease was present. Clearance was achieved with a single treatment in 15 lesions and in all of the remaining nine lesions after a second treatment. The treatment was well tolerated, with pain absent or mild during treatment in 22 lesions, with only one lesion requiring local anaesthesia. Over the 10 days following treatment, no pain was associated with 21 treated lesions. During a 12 month follow-up period, two Bowen's disease lesions recurred. The overall complete response rate was 92%. Scarring was evident following PDT in only three lesions. Photodynamic therapy using this portable non-laser light source appears to be an effective and well-tolerated treatment for Bowen's disease and actinic keratoses.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 1978-10-01
    Print ISSN: 0028-0836
    Electronic ISSN: 1476-4687
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Published by Springer Nature
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-17
    Description: The paper describes the general design, instrumentation, and ground control system of the International Ultraviolet Explorer (IUE) satellite, which will serve as an astronomical observatory providing both high and low resolution UV spectra of sources other than the sun. Basic data are given on the telescope, the UV-visible converter, the spectrograph optics, the camera response, and the communications systems.
    Keywords: SPACECRAFT INSTRUMENTATION
    Type: Nature; 275; Oct. 5
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2016-06-07
    Description: The fine error sensor located within the Princeton Experiment Package (PEP) is designed to aquire a star within its field of view to hold the spacecraft within plus or minus one-tenth of an arc second in pitch, and plus or minus three-arc seconds about the yaw axis. Pointing accuracy and stability tests of the fine error sensor exceeded the plus or minus 0.1 arc second requirement.
    Keywords: NAVIGATION
    Type: Significant Accomplishments in Technol., 1972; p 22-24
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...