ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Language
  • 1
    Publication Date: 2022-09-29
    Description: Blue whales produce regionally-distinct songs. In over a decade since McDonald and colleagues published a summary of biogeographic differences in blue whale songs worldwide, multiple new publications have explored the seasonality and distribution of those songs. We review the spatial and temporal occurrence of previously-defined song types and report several new blue whale song types. At least thirteen songs believed to be produced by blue whales are now known worldwide, five more than reported in the previous review. In the North Pacific Ocean there are three blue whale songs: the well-studied Northeast Pacific song, the Central North Pacific (previously called Northwest and North Pacific) song, and a new song recorded off Hokkaido, Japan. There is spatial overlap of the Northeast Pacific and Central North Pacific songs in the Gulf of Alaska. Similarly, the new song co-occurs with the Central North Pacific song off Hokkaido. Only one blue whale song occurs in the North Atlantic. At least nine songs are present in the Southern Hemisphere. The Antarctic blue whale song is the most widely distributed, occurring in the Southern Ocean as well as seasonally extending into the other oceans of the Southern Hemisphere. The Indian Ocean has the largest variety of blue whale songs, with new data suggesting the Southwest Indian Ocean song should have type locality Madagascar, with Diego Garcia possibly another song-type. Southeast Pacific contains two distinct, co-occurring songs. We report a new song in the South Atlantic, near South Georgia Island, that also occurs seasonally off Ascension Island. Occasionally blue whale songs were recorded outside of their reported range, indicating individuals at times roam more broadly. However, this is not a common occurrence. This new information and finer details of occurrence will enable further development of hypotheses for blue whale population structure based on acoustics.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Conference , notRev
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 17 (1978), S. 2842-2847 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 1277-1281 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe a dc volume H− source, employing multicusp plasma confinement, which has been constructed for use with the TRIUMF cyclotron. An extracted H− current density of 12 mA/cm2 has been obtained. Beam emittance and brightness have been measured as a function of current density and beam fraction. Beam brightness values for normalized beam emittances of the order of 0.2 πmm mrad at 81% beam fraction are typically 10 mA/(mm mrad)2 [equivalent rms B=223 mA/(mm mrad)2].
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 184 (1959), S. 458-459 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Trials were conducted with spayed Romney ewes during January 1957-May 1959. The 12 spayed ewes previously mentioned2 were used during January-July 1957. For the remaining trials these ewes and an additional 8 spayed animals of similar age and breeding were treated. In each trial three groups of ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 178 (1956), S. 1472-1473 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The complexity of the external orifice of the cervix, particularly in aged ewes, presents a difficulty in the collection of a cervical specimen uncontaminated with vaginal mucus. With experience mucus was readily obtained through use of a Coldite vaginal speculum and glass rod, or directly from ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 177 (1956), S. 343-343 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Two experiments, observing the effect of supplements of 0-2 per cent dl-methionine and 0-066 per cent choline (providing an equivalent quantity of labile methyl groups as 0-2 per cent methionine) on the response to supplementary folic acid, have been completed using White Leghorn chickens up to six ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 186 (1960), S. 548-549 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] At temperatures between 20 and 50 C. water is absorbed into the amorphous regions of the granules, which swell about 30 per cent by volume4. The crystallites remain largely intact, but on heating the suspension at a temperature above 60 some of the crystallites are disrupted, and the granules ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A 2.45 GHz electron cyclotron resonance (ECR) ion source with a single mode resonator is being developed to produce high efficient single charged ion beams from exiguous gaseous elements. The source is intended to produce short and long half-life radioactive ion beams as well as stable ion beams for low and high energy experiments at ISAC [J. M. Poutissou, Proceedings of the ISAC Workshop (1994)]. It is obvious that for the radioactive ion beam production, the gas and ion transient time and the overall ionization efficiency are the most important parameters. The transient time is measured using ultrafast peizoelectric gas valve which could operate up to a frequency of 2 kHz. A unique feature of the source is that the plasma chamber is considerably smaller (∼170 times) than its resonance cavity in order to minimize the transient time. Quartz tubes with various diameters (5–20 mm) and 80 mm long are tested as the plasma chamber and the results are discussed. The effect of the transfer tube length, which links the target and the ion source on the transient time is also described. An axially symmetric five electrode extraction system containing three multiaperture electrodes was used to extract the beam. The source, including ECR coils and extraction system is placed in the middle of a 60 cm×60 cm×90 cm vacuum box to simulate the ISAC target module conditions. The preliminary results of the molecular and ion transient time studies, beam efficiency studies are also presented in this article. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 700-707 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A JEOL 200CX high-resolution transmission electron microscope with point-to-point resolution of 2.5 A(ring) has been modified to achieve an ultrahigh-vacuum specimen environment (∼10−9τ). In situ heating and evaporation are provided in the specimen viewing position, where high resolution can be maintained at temperatures exceeding 600 °C. Our design employs complete differential pumping of the specimen chamber and the use of a He-cooled cyroshield at the specimen for best vacuum attainment. Our design philosophy permits the instruments to be used for a wide variety of in situ experiments, including low-pressure (〈10−1τ) gas reaction.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A 2.45 GHz electron cyclotron resonance ion source has been designed and built to ionize radioactive atoms and produce single charged ion beams for the isotope separator and accelerator at TRIUMF. The source is characterized by its short axial length (8 cm) and the small pair of magnetic coils (diam=φ26 cm) placed adjacent to the source cavity. A small diameter quartz tube is inserted in the cavity to confine the plasma to a small volume and to shorten total ion transient time for the exotic gaseous elements with short and intermediate half life. The computer code POISSON is used to design the magnetic coils. A three-electrode extraction system simulated with the code IGUNE is used to study the beam extraction efficiency. In this article the design of the source, extraction system, and the preliminary results on beam emittance and energy spread are presented; the results on ion transient time, ionization efficiency, and beam extraction efficiency are presented in a separate article. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...