ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 1979-12-01
    Print ISSN: 0040-6090
    Electronic ISSN: 1879-2731
    Topics: Physics
    Published by Elsevier
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Microanalytical Investigations of the Precipitation Behaviour of Commercial Aluminized and Chromium-Aluminized Coatings on Ni-Base Alloys and Austenitic SteelsThe precipitation and diffusion behaviour of commercial aluminized and chromiumaluminized coatings on nickel-base alloys and austenitic steels was studied by aid of an electron probe microanalyzer. It is shown, that the protected nickel-base alloys all have a similar layer structure: an external NiAl-layer, which is delimited by an intermediate CrNi-(Mo)-layer to a small Al- containing mixed crystal zone. In the case of aluminized austenitic steels only a very small NiAl-layer can be detected, followed by an extended Al-containing mixed crystal. These layers on Fe-base alloys are predamaged by a perforated zone, due to the Kirkendall-effect. A previous chromium diffusion prevents this effect, but the diffusion behavior was not influenced during an extended heat treatment. The protected nickel-base alloys showed the best durability during long time oxidation tests.
    Notes: Mit Hilfe eines Elektronenstrahlmikroanalysators wurde das Ausscheidungs- und Diffusionsverhalten von kommerziell hergestellten Alitier- und Chromalitierschichten auf Nickelbasislegierungen und austenitischen Stählen untersucht. Dabei zeigte es sich, daß die geschützten Nickelbasislegierungen alle einen ähnlichen Schichtaufbau aufweisen: eine NiAl-Außenschicht, die durch eine chromhaltige Zwischenschicht gegen den schmalen Al-haltigen Mischkristall abgegrenzt ist. Bei den austenitischen Stählen tritt nur eine sehr schmale NiAl-Zone auf, auf die ein ausgedehnter Al-haltiger Mischkristallbereich folgt. Diese Schichten auf Eisenbasislegierungen sind durch eine Kirkendall-Lochbildung vorgeschädigt. Eine der Alitierung vorangegangene Chromierung verhindert die Lochbildung, allerdings beeinflußt sie das Diffusionsverhalten der Schicht bei längerem Wärmebehandeln kaum. Bei den orientierenden Langzeitoxidationstests zeigt sich die überlegene Beständigkeit der alitierten- und chromalitierten Nickelbasislegierungen.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 12 (1981), S. 315-324 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Behaviour of Hip - Joint Endoprostheses under quasi-static and dynamic LoadClinical experience with total-hip endoprostheses has shown that the following problems take priority: - Loosening of the socket (acetabular cup) and the femoral prosthesis - Fracture of the femoral prosthesis - Loosing due to deep infection.Accordingly aims the research at locating the biological and mechanical reasons for the failures as well as testing alternative solutions such as - methods of fixation - construction of protheses - new materials and finishing methods. This publication concerns areas of the mechanical side of the problem.The comparison between the original system of proximal femur and acetabulum and the implanted prosthetic system shows changes in the stiffness of the systems depending on the different types of implanted endoprostheses.The influence of the frequency of loading on the deformation of the system is investigated in a frequency range between quasi-static and dynamically changing loads.The movements between implanted cup and neighbouring pelvic bone during cyclic load is measured.The results of these examinations give clues concerning qualitative and quantitative repercussions from the different endoprosthetic systems under conditions optimal in view of true comparison, and possible or desirable alternative solutions of the problem in view of construction and material.
    Notes: Aufgrund bisher vorliegender klinischer Erfahrungen mit Hüftgelenks-Totalendoprothesen nehmen folgende Problemstellungen eine gewisse Priorität ein: - Pfannen- und Schaftlockerungen, - Schaftbrüche - Infektlockerungen.Dementsprechend konzentriert sich die Forschung auf die Ermittlung der biologischen und mechanischen Ursachen des Fehlverhaltens sowie auf die Erprobung alternativer Lösungen hinsichtlich - Fixationsmethodik - Konstruktion von Endoprothesen - Werkstoff und Fertigungsmethoden.Die vorliegende Arbeit bezieht sich auf Teile des mechanischen Komplexes dieser Problemstellung.Durch vergleichende Untersuchungen am Original- sowie am Implantatsystem „proximaler Femur/Hüftgelenkspfanne“ wird die Änderung der Steifigkeit infolge Implantation unterschiedlicher Typen von Endoprothesen ermittelt.Der Einfluß der Belastungsfrequenz auf die Deformationsverhältnisse in diesem System wird in einem Frequenzbereich überprüft, der sich von quasi-statischer bis zu dynamisch-wechselnder Belastung erstreckt.Die Relativbewegung zwischen implantierter Hüftgelenkspfanne und benachbartem knöchernen Bereich wird bei zyklischer Belastung erfaßt und messend verfolgt.Die Befunde geben punktuelle Hinweise hinsichtlich qualitativer und quantitativer Auswirkungen unterschiedlicher endoprothetischer Maßnahmen unter Bedingungen optimierter Vergleichbarkeit sowie hinsichtlich möglicher oder zweckmäßiger alternativer Lösungen im konstruktiven und stofflichen Bereich der anstehenden Fragestellungen.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...