ISSN:
1040-7685
Keywords:
open tubular columns
;
liquid chromatography
;
immobilized Carbowax 20M
;
stationary phase swelling
;
effect of mobile phases
;
Chemistry
;
Analytical Chemistry and Spectroscopy
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
Notes:
Polyurethane immobilized Carbowax 20M stationary phase was used in capillary liquid chromatography. Mobile phases tested in this study (distilled water and aqueous solutions of the following solvents: 5.5% methanol, 5% acetone, 5, 10, 20% acetonitrile, 0.815% chloroform, 0.178% benzene and up to 0.00095% hexane) cause considerable swelling of the stationary phase polymeric film. The stationary phase swelling index reached a maximal value of S = 131. Diffusion coefficients in the stationary phase vary between 2.6 × 10-5 and 6.5 × 10-4 mm2 s-1.
Additional Material:
8 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/mcs.1220040403