Notes:
Mass transfer rates and flooding limits are basic to the use of packed columns for liquid-liquid extraction. The input of pulsing energy increases transfer rates and promotes counterflow of the two phases. The wetting characteristics of the packing influence performance.The toluene-benzoic acid-water system was used to observe the performance of a 2-in. diam. column containing ceramic (hydrophilic) rings, polyethylene (hydrophobic) rings, or a sieve-plate cartridge. The packed columns showed lower flooding limits than the plate column, but polyethylene packing gave highest transfer rates and capacities. The pulsing energy input was much lower for the plastic packing to effect a higher transfer rate.Flooding limits for the pulsed, packed columns were lower than for packed columns which were not pulsed. Columns packed with rings so that the ratio of diameter to packing size was 4:1 gave higher flooding limits and better performance than a ratio of 8:1. The use of the two types of packing in alternating bands resulted in a performance intermediate between that of each packing employed separately, and no advantage was indicated in reference to flooding limits or transfer rates.