ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Years
  • 1
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Key engineering materials Vol. 309-311 (May 2006), p. 953-956 
    ISSN: 1013-9826
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: A novel composite of biodegradable Poly-L-lactic acid (PLLA) with the deposition of the nanosized amorphous calcium phosphate (NCP) particles was developed as tissue engineering scaffold. To improve the minor intrinsic healing capacity of cartilage tissue, the porous composite with desired degradation rate was incorporated with basic fibroblast growth factor (bFGF) andevaluated in the in vivo environment. Full-thickness defects were created in the weight-bearing surface of the femoral condyles in a rabbit model. The defect was filled with and without NCP/PLLA scaffold as a carrier of bFGF. Gross morphology for the test implant showed that the defect was filled with regenerated tissue. It resembled cartilaginous tissue and restored the contour of the condyle at 8 weeks after operation. For the untreated control, no cartilage-like tissue wasobserved at all defects. Histological analysis revealed neochondrogenesis and clusters of cartilaginous extracellular matrix observed with safranin-O staining at 4 weeks for the NCP/PLLA with bFGF treated defects. At 8 weeks after operation, well-formed and mature cartilage was resurfaced the defects. While only fibrous tissue replacement was observed for the control either at4 or 8 weeks. Special staining for cartilage indicated the presence of highly sulfatedglycosaminoglycans and collagen, which were the major extracellular matrices of cartilage. This investigation showed the potential of NCP/PLLA loaded with bFGF in the study of in situ-transplantable carrier to improve healing of cartilage tissue lesion
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Key engineering materials Vol. 309-311 (May 2006), p. 399-402 
    ISSN: 1013-9826
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: The objective of this study was to evaluate the interface shear strength and the responses of osteoblast-like cells to titanium implants with a sandblasted and acid-etched surface modified by alkali and heat treatments (SLA-AH). The implants with machined and SLA surface served as controls. Each type of implant was characterized by scanning electron microscopy (SEM) and energy-dispersive x-ray (EDX) analysis. In vitro assays were made using human osteoblast-like cellculture on different surfaces. The rectangle plates were also transcortically implanted into the proximal metaphysis of New Zealand White rabbit tibiae. After 4, 8 and 12 weeks implantation, mechanical and histological assessments were performed to evaluate biomechanical and biological behavior in vivo. By SEM examination, SLA surface combined with AH treatments revealed a macro-rough surface with finely microporous structure. The in vitro assays showed that theSLA-AH surfaces exhibited more extensive cell deposition and improved cell proliferation as compared with controls. Pull-out test demonstrated that the SLA-AH treated implants had a higher mechanical strength than the controls at all interval time after implantation. Histologically, the test implants revealed a significantly greater percentage of bone-implant contact when compared with controls. The results of this study suggest that a useful approach by combined processes couldoptimize implant surfaces for bone deposition and produce distinct biological surface features
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...