ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 215-247 
    ISSN: 0197-8462
    Keywords: electric field ; 60-Hz ; detection ; psychophysics ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Rats partially deprived of food were trained individually to press a lever in the presence of a vertical, 60-Hz electric field and not to press in its absence. Correct detections that occurred during brief, 3- or 4-s trials occasionally produced a food pellet. The probability of detecting the field was found to increase as field strength increased. The threshold of detection, ie, the field strength required for detections at a probability of 0.5 after correction for errors, was generally between 4 and 10 kV/m. The range of field strengths between almost zero and almost 100% correctness of detection was approximately 8 kV/m. A logistic function provided a good description of the increase in the detection probability with increasing field strength. These performances occurred reliably in 19 rats, some of which were studied for 2 years. Control procedures showed that the behavior required that the rat be in the electric field; the behavior was not controlled by any of several potentially confounding variables.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 79-88 
    ISSN: 0197-8462
    Keywords: circular waveguide exposure system ; radiofrequency dosimetry ; rhesus monkey ; radiofrequency exposure ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A 275-MHz exposure system, consisting of a circular waveguide irradiator and a transparent plastic animal cage, has been developed to accommodate rhesus monkeys weighing up to 15 kg. The vertically oriented waveguide is composed primarily of stainless steel and is fitted with an inner cage fabricated from a tubular section of acrylic plastic. Circularly polarized electromagnetic energy at 275 MHz, either pulsed or continuous wave (CW), can be propagated from the removable top section of the waveguide. The cage is designed to function as the monkey's permanent home. It is fitted with a lever-actuated behavioral performance device on which the monkey responds according to a predetermined schedule to obtain a daily food ration. The system can be adapted to provide for the collection of metabolic and physiologic data as well. Dosimetric measurements were conducted with six rhesus monkeys weighing 3.0-7.2 kg and with a 4-kg model. The dosimetric results show that about one-third of the net incident energy is absorbed by a subject in this system at a normalized specific absorption rate (SAR) of 0.33 (W/kg)/(mW/cm2).
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 233-246 
    ISSN: 0197-8462
    Keywords: operant behavior ; observing-responses ; radiofrequency radiation ; colonic temperature ; rhesus monkeys ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Five food-deprived rhesus monkeys were exposed to 225-MHz continuous-wave, and 1.3-GHz, and 5.8-GHz pulsed radiation to determine the minimal power densities affecting performance. The monkeys were trained to press a lever (observing-response) thereby producing signals that indicated availability of food. In the presence of the aperiodically appearing food signals, a detection response on a different lever was reinforced by a food pellet. Continuous, stable responding during 60-min sessions developed and was followed by repeated exposures to radiofrequency radiation. The subjects, restrained in a Styrofoam chair, were exposed to free-field radiation while performing the task. Colonic temperature was simultaneously obtained. Observing-response performance was impaired at increasingly higher power densities as frequency increased from the near-resonance 225 MHz to the above-resonance 5.8 GHz. The threshold power density of disrupted response rate at 225 MHz was 8.1 mW/cm2; at 1.3 GHz it was 57 mW/cm2, and at 5.8 GHz it was 140 mW/cm2. These power densities were associated with reliable increases in colonic temperatures above sham-exposure levels. The mean increase was typically in the range of 1°C, and response-rate changes were not observed in the absence of concomitant temperature increases. In these experiments increase of colonic temperature was a much better predictor of behavioral disruption than was either the power density of the incident field or estimates of whole-body-averaged rates of energy absorption.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 183-198 
    ISSN: 0197-8462
    Keywords: operant behavior ; observing-responses ; microwaves ; vigilance ; dosimetry ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effects of microwave irradiation at two different frequencies (1.28 and 5.62 GHz) on observing-behavior of rodents were investigated. During daily irradiation, eight male hooded rats performed on a two-lever task; depression of one lever produced one of two different tones and the other lever produced food when depressed in the presence of the appropriate tone. At 5.62 GHz, the observing-response rate was not consistently affected until the power density approximated 26 mW/cm2 at 1.28 GHz, the observing-response rate of all rats was consistently affected at a power density of 15 mW/cm2. The respective whole-body specific absorption rates (SARs) were 4.94 and 3.75 W/Kg. Measurements of localized SAR in a rat-shaped model of simulated muscle tissue revealed marked differences in the absorption pattern between the two frequencies. The localized SAR in the model's head at 1.28 GHz was higher on the side distal to the source of radiation. At 5.62 GHz the localized SAR in the head was higher on the proximal side. It is concluded that the rat's observing behavior is disrupted at a lower power density at 1.28 than at 5.62 GHz because of deeper penetration of energy at the lower frequency, and because of frequency-dependent differences in anatomic distribution of the absorbed microwave energy.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 10 (1989), S. 65-76 
    ISSN: 0197-8462
    Keywords: pulsed microwaves ; behavior ; macaca mulatta ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The current safety standards for radiofrequency and microwave exposure do not limit the peak power of microwave pulses for general or occupational exposures. While some biological effects, primarily the auditory effect, depend on pulsed microwaves, hazards associated with very high peak-power microwave pulses in the absence of whole-body heating are unknown. Five rhesus monkeys, Macaca mulatta, were exposed to peak-power densities of 131.8 W/cm2 (RMS) while performing a time-related behavioral task. The task was composed of a multiple schedule of reinforcement consisting of three distinct behavioral components: inter-response time, time discrimination, and fixed interval. Trained monkeys performed the multiple schedule during exposure to 1.3-GHz pulses at low pulse-repetition rates (2-32 Hz). No significant change was observed in any behavior during irradiation as compared to sham-irradiation sessions. Generalization of these findings to experimental results with higher peak-power densities, other pulse rates, different carrier frequencies, or other behaviors is limited.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...