    Publication Date: 2020-12-14
    Description: The objective of this work is to perform a purely empirical assessment of the actual capabilities of the horizontal-to-vertical (H/V) spectral ratio technique to provide reliable and relevant information concerning site conditions and/or site amplification. This objective has been tackled through the homogeneous (re)processing of a large volume of earthquakes and ambient noise data recorded by different research teams in more than 200 sites located mainly in Europe, but also in the Caribbean and in Tehran. The original recordings were first gathered in a specific database with information on both the sites and recorded events. Then, for all sites close to an instrumented reference, average site-to-reference spectral ratios (“spectral ratio method” (SSR)) were derived in a homogeneous way (window selection, smoothing, signal-to-noise ratio threshold, averaging), as well as H/V ratios (“HVSRE–RF”) on earthquake recordings. H/V ratios were also obtained from noise recordings at each site (either specific measurements, or extracted from pre- or post-event noise windows). The spectral curves resulting from these three techniques were estimated reliable for a subset of 104 sites, and were thus compared in terms of fundamental frequency, amplitude and amplification bandwidth, exhibiting agreements and disagreements, for which interpretations are looked for in relation with characteristics of site conditions. The first important result consists in the very good agreement between fundamental frequencies obtained with either technique, observed for 81% of the analyzed sites. A significant part of the disagreements correspond to thick, low frequency, continental sites where natural noise level is often very low and H/V noise ratios do not exhibit any clear peak. The second important result is the absence of correlation between H/V peak amplitude and the actual site amplification measured on site-to-reference spectral ratios. There are, however, two statistically significant results about the amplitude of the H/V curve: the peak amplitude may be considered as a lower bound estimate of the actual amplification indicated by SSR (it is smaller for 79% of the 104 investigated sites), and, from another point of view, the difference in amplitude exhibits a questioning correlation with the geometrical characteristics of the sediment/basement interface: large SSR/HV differences might thus help to detect the existence of significant 2D or 3D effects.
    Description: Published
    Description: 75-108
    Description: 4.1. Metodologie sismologiche per l'ingegneria sismica
    Description: JCR Journal
    Description: reserved
    Keywords: Microtremor ; H/V ; Site effects ; SESAME ; 04. Solid Earth::04.02. Exploration geophysics::04.02.06. Seismic methods ; 04. Solid Earth::04.06. Seismology::04.06.09. Waves and wave analysis
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2017-04-04
    Description: For an optimal analysis of the H/V curve, it appears necessary to check the instrument signal to noise ratio in the studied frequency band, to ensure that the signal from the ground noise is well above the internal noise. We assess the reliability and accuracy of various digitizers, sensors and/or digitizer-sensor couples. Although this study is of general interest for any kind of seismological study, we emphasize the influence of equipment on H/V analysis results. To display the impact of the instrumental part on the H/V behavior, some series of tests have been carried out following a step-by-step procedure: first, the digitizers have been tested in the lab (sensitivity, internal noise...), then the three components sensors, still in the lab, and finally the usual user digitizers-sensors couple in lab and outdoors. In general, the digitizer characteristics, verified during this test, correspond well to the manufacturer specifications, however, depending on the digitizer, the quality of the digitized waveform can be very good to very poor, with variation from a channel to another channel (gain, time difference etc.). It appears very clearly that digitizers need a warming up time before the recording to avoid problems in the low-frequency range. Regarding the sensors, we recommend strongly to avoid the use of “classical” accelerometers (i.e., usual force balance technology). The majority of tested seismometers (broadband and short period, even 4.5 Hz) can be used without problems from 0.4 to 25 Hz. In all cases, the instrumentation should be checked first to verify that it works well for the defined study aim, but also to define its limit of use (frequency, sensitivity...).
    Description: Published
    Description: 3-31
    Description: 4.1. Metodologie sismologiche per l'ingegneria sismica
    Description: JCR Journal
    Description: reserved
    Keywords: H/V technique ; Instrumentation ; Microtremors ; Site effects ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques