Abstract A method of glow discharge atomic emission spectroscopy (GD-AES) is described for the determination of rare earth elements (REEs) after separation and preconcentration by micro-column packed with immobilized 1-phenyl-3-methyl-4-benzoyl-5-pyrazone (PMBP) on microcrystalline naphthalene. The graphite electrode with solution residue on its surface was used as a cathode. Various factors (the form of cathode, working condition) influencing the determination of the analytes were studied in detail. Under the experimental conditions selected, the detection limits for the determination of La, Nd, Eu, Dy and Y are 0.24, 0.32, 0.01, 0.07 and 0.06 μg/mL, respectively, with relative standard deviations (RSDs) in the range of 5–10%. The method was applied to determine La, Nd, Eu, Dy and Y in geological samples, and the analytical results are in good agreement with the reference values.