Description / Table of Contents:
Summary A simple and rapid analytical method has been developed for the direct determination of trace quantities of thallium in nickel and cobalt-base heatresisting alloys by graphite furnace atomic absorption spectrometry. Hydrofluoric acid, sulphuric acid, and hydrogen peroxide were used for the dissolution of a wide variety of these alloys. The interferences of matrix elements and acids were eliminated. The absorbance of thallium is constant over a wide range of ashing temperatures. Synthetic standard solutions composed of nickel or cobalt matrix and thallium were used for calibration. The detection limit for thallium by this method is 0.2 ppm in the sample. Mechanisms of the interferences are discussed.
Notes:
Zusammenfassung Ein Verfahren zur AAS-Bestimmung von Thallium in verschiedenartigen Cobalt- und Nickellegierungen wird beschrieben. Zur Auflösung der Probe werden Flußsäure, Schwefelsäure und Wasserstoffperoxid verwendet. Störungen durch Matrixelemente und durch die Säuren konnten beseitigt werden. Die Thalliumabsorption ist über einen weiten Temperaturbereich bei der Veraschung konstant. Zur Eichung dienen synthetische Lösungen von Cobalt- bzw. Nikkelmatrix und Thallium. Die Nachweisgrenze für Thallium beträgt 0,2 ppm. Die Mechanismen der Störungen werden diskutiert.