ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. ; Stafa-Zurich, Switzerland
    Key engineering materials Vol. 399 (Oct. 2008), p. 205-210 
    ISSN: 1013-9826
    Source: Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: The paper describes the biomechanical behavior of a cervical implanted unit (CIU) in two conditions: during the physiological and extreme loading. In order to reveal these behaviors, the anatomical structure composed by the C2 and C3 cervical vertebras was implanted using a plate-screws metal structure. The implant was design to perform dynamical, by allowing longitudinal, transversal and rotational movements. The physiological conditions were simulated by the pulsatory negative loading, while the extreme loading was simulated by the alternant symmetrical loading. The tests reveal two behaviors: the durability of the CIU in the physiological loading conditions and the failure of the structure under extreme load
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2020-03-11
    Description: Selective Laser Sintering is a flexible additive manufacturing technology that can be used for the fabrication of high-resolution parts. Alongside the shape and dimension of the parts, the mechanical properties are essential for the majority of applications. Therefore, this paper investigates dimensional accuracy and mode I fracture toughness (KIC) of Single Edge Notch Bending samples under a Three Point Bending fixture, according to the ASTM D5045-14 standard. The work focuses on the influence of two major aspects of additive manufacturing: material type (Polyamide PA2200 and Alumide) and part orientation in the building environment (orientations of 0°, 45° and 90° are considered). The rest of the controllable parameters remains constant for all samples. The results reveal a direct link between the sample densities and the dimensional accuracy with orientation. The dimensional accuracy of the samples is also material dependent. For both materials, the angular orientation leads to significant anisotropic behavior in terms of KIC. Moreover, the type of material fundamentally influences the KIC values and the fracture mode. The obtained results can be used in the development of additive manufactured parts in order to obtain predictable dimensional tolerances and fracture properties.
    Electronic ISSN: 2073-4360
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Process Engineering, Biotechnology, Nutrition Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-11-09
    Description: As additive manufacturing (AM) becomes more accessible, correlating process parameters with geometric and mechanical properties is an important topic. Because the number of process variables in AM is large, extensive studies must be conducted in order to underline every particular influence. The study focuses on two variables—part orientation in the orthogonal horizontal plane and energy density—and targets two outcomes—geometric and tensile properties of the parts. The AM process was conducted on selective laser sintering (SLS) machine EOS Formiga P100 using EOS white powder polyamide (PA2200). After finishing the sinterization process, the parts were postprocessed, measured, weighted, and mechanically tested. The geometric evaluation and mass measurements of every sample allowed us to compute the density of all parts according to the sinterization energy and orientation, and to determine the relative error of every dimension. By conducting the tensile testing, the elastic and strength properties were determined according to process variables. A linear trend regarding sample density and energy density was identified. Also, large relative dimensional errors were recorded for the lowest energy density. Mechanical properties encountered the highest value for the highest energy density at a 45° orientation angle.
    Electronic ISSN: 2073-4360
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Process Engineering, Biotechnology, Nutrition Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2021-02-10
    Description: Multiple causes can determine the disturbance of natural equilibrium in a population of a species, with a common one being the presence of invasive competitors. Invasives can drive native species to the resettlement of the trophic position, changing reproduction strategies or even daily normal behaviours. Here, we investigated the hypothesis that more effective anatomical features of an intruder (Faxonius limosus) come with increased boldness behaviour, contributing to their invasion success in competition against the native species (Pontastacus leptodactylus). We tested the boldness of specimens representing the two species by video-based assessment of crayfish individuals’ attempts to leave their settlement microenvironment. The experiment was followed by a series of measurements concerning chelae biometry, force and muscle energetics. The native species was less expressive in terms of boldness even if it had larger chelae and better muscular tissue performance. In contrast, because of better biomechanical construction of the chelae, the invasive species was capable of twice superior force achievements, which expectedly explained its bolder behaviour. These findings suggest that, in interspecific agonistic interactions, the behaviour strategy of the invasive crayfish species is based on sheer physical superiority, whereas the native crayfish relies on intimidation display.
    Electronic ISSN: 2296-701X
    Topics: Biology
    Published by Frontiers Media
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2021-08-05
    Description: In modern endodontics, nickel-titanium (NiTi) rotary instruments are used on a large scale for root canal shaping. Nevertheless, the separation of an instrument is a serious concern during shaping. The aim of this study is to determine and compare the torsional fracture characteristics of three types of NiTi endodontic instruments, each with different cross-section designs and movements performed during root canal shaping: Endostar E3 (Endostar, Poldent Co. Ltd., Warsaw, Poland); Reciproc R25 (VDW, Munich, Germany); and Protaper Next X2 (Dentsply Maillefer, Ballaigues, Switzerland). Fifteen instruments are used in this study, divided in three groups (n = 5): Group Endostar, Group Reciproc and Group Protaper. For testing, each instrument is used to shape five simulated root canals, following which its torsional stress to failure is measured. The fracture lengths of all three groups are roughly between 2 and 3 mm from the tip. Higher values of the moment of torsion in fracture, and smaller values of the maximum twisting angle are observed for Group Endostar, as well as closer to circular cross-sections. However, the values of the shear tension are similar for all three groups, because the disadvantage given by the fracture section shape for Groups Reciproc and Protaper is compensated either by size or by intrinsic properties of the instrument material. For the shear tension the Endostar values are insignificantly increased (Kruskal–Wallis test, p = 0.207), and in the case of the maximum twist angle the Protaper values are insignificantly increased (Kruskal–Wallis test, p = 0.287). Because of the instruments shape and conicity, the analysis had to be carried out separately with regard to the length of the fractured tip. Rules-of-thumb are extracted from the study for current practice: if a blockage of the first 2 to 3 mm part of the tip can be anticipated (by the excessive curving of the instrument), the handpiece must be adjusted to torque values that do not exceed 1.5 to 2.5 N · cm for Endostar and 1 to 2 N · cm for Reciproc and Protaper instruments.
    Electronic ISSN: 2076-3417
    Topics: Natural Sciences in General
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2021-09-03
    Description: The purpose of this study is to identify the stress levels that act in inlay and onlay restorations, according to the direction and value of the external force applied. The study was conducted using the Finite Element Method (FEM) of three types of ceramics: pressed lithium disilicate and monolith, zirconia, and three different adhesive systems: self-adhesive, universal, and dual-cure cements. In addition to FEM, the inlay/onlay-dental structure interface analysis was performed by means of Scanning Electron Microscopy (SEM). The geometric models were reconstructed based on computer tomography images of an undamaged molar followed by geometrical procedures of inducing the inlay and onlay reconstructions. The two functional models were then simulated for different orientations of external force and different material properties, according to the considered adhesives and ceramics. The Scanning Electron Microscopy (SEM) was conducted on 30 extracted teeth, divided into three groups according to the adhesive cement type. Both FEM simulation and SEM investigations reveal very good mechanical behavior of the adhesive-dental structure and adhesive-ceramic interfaces for inlay and onlay reconstructions. All results lead to the conclusion that a physiological mastication force applied, regardless of direction, cannot produce a mechanical failure of either inlay or onlay reconstructions. The adhesive bond between the restorations and the dental structure can stabilize the ceramic restorations, resulting in a higher strength to the action of external forces.
    Electronic ISSN: 1996-1944
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...