ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Angewandte Makromolekulare Chemie 211 (1993), S. 141-155 
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die after-glow Plasmapolymerisation wird als neues Verfahren zur Herstellung polymerer Schichten aus ungesättigten Monomeren vorgestellt. Als Monomeres wird ein optisch aktiver Acrylsäureester verwendet. Die Abscheidekinetik wird durch Variation von Monomerfluß, Fluß und Art des Hilfsgases (He, Ne, Ar, Kr) Abstand zwischen Plasma und Substrat, Druck und nomineller Plasmaleistung untersucht. Die erhaltenen Polymeren sind optisch aktiv und lassen sich mittels IR_Spektroskopie nicht von den in Masse polymerisierten Analoga unterscheiden. Die Polymeren sind meist vernetzt und damit unlöslich. NMR-Spektren von Löslichen Proben zeigen, daß es sich um atktische Polymere handelt. Die after-glow Plasmapolymerisation verläuft über einen radikalischen Kettenwachstumsmechanismus. Membranchichten aus den erhaltenen Polymeren sind in der Lage, Racemate zu trennen.
    Notes: After-glow plasma polymerization is described as a new method to prepare polymeric layers from unsaturated monomers. An optically active acrylic monomer is used in this investigation. The deposition rates are given as functions of plasma power, pressure, distance between plasma and deposition zone, flux and kind of auxiliary gas (He, Ne, Ar, Kr) and of monomer flux. The polymers prepared are optically active, the IR spectra comply with those of polymers synthesized in bulk. Mostly the polymers prepared by after-glow plasma polymerization are cross-linked and therefore insoluble. NMR spectra of soluble samples show that the polymers are atactic. After-glow plasma polymerization occurs by a radical chain growth mechanism. Membranes made from these polymers are able to separate racemates.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Angewandte Makromolekulare Chemie 164 (1988), S. 115-124 
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Schläuche mit kleinem Durchmesser (4 mm) aus Silikonkautschuk wurden mittels einer Glimmentladungstechnik mit Vinylmethylacetamid (VIMA) gepfropft. Die Entladungsparameter wurden so gewählt, daß eine Pfropfung ausschließlich auf der inneren Oberfläche der Schläuche stattfand. Der Einfluß der Pfropfbedingungen auf den Reaktionsumsatz wurde mit Hilfe gravimetrischer Messungen und durch Kontaktwinkelmessungen untersucht. Erhöhung der Entladungsspannung und Nachbehandlung bei erhöhtem Monomerdampfdruck führten zu einer Steigerung des Umsatzes. Ein Einfluß des Monomerdampfdrucks während der Entladung auf den Reaktionsumsatz wurde nicht beobachtet. In vitro Versuche zur Blutverträglichkeit mit humanem Blutplasma ergaben Unterschiede zwischen gepfropften und ungepfropf ten Materialien. In Plasma, das mit VIMA gepfropften Oberflächen in Kontakt war, wurden eine Verlängerung der partiellen Thromboplastinzeit (PTT) sowie erniedrigte Werte von Faktor V und Plättchenfaktor 4 gefunden, wogegen keine Unterschiede in der Freisetzung von Fibrinopeptid A festgestellt werden konnten. Die Adhäsion von Blutplättchen an gepfropften Schläuchen war deutlich geringer als an ungepfropften.
    Notes: Small diameter silicone rubber tubings were grafted with vinyl methyl acetamide using a glow discharge treatment. Discharge conditions were chosen which allowed grafting exclusively on the inner surface of the tubings. Increasing the voltage as well as a posttreatment at increased monomer vapor pressures leads to higher conversions as a posttreatment at increased monomer vapor pressures leads to higher conversions as determined by contact angle measurement and gravimetry; no influence of the discharge pressure could be observed. Human blood plasma exposed to the grafted tubings showed some alterations in comparison to blood plasma exposed to ungrafted tubings. A prolongation of the activated partial thromboplastin time and lower levels of factor V and platelet factor 4 were measured, while almost no differences in the generation of fibrinopeptide A could be noticed. Platelet adhesion on grafted tubings was less than on unmodified tubings.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Angewandte Makromolekulare Chemie 120 (1984), S. 177-191 
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die Behandlung von isotaktischem Polypropylen mit Corona-Entladung in N2 und CO2 wurde mit Hilfe von Kontaktwinkel-Messungen und ESCA untersucht. Die elektrischen Charakteristika der Entladung sowie der Einfluß indirekter Parameter (Zeitpunkt des Luftzutritts und Alterung) und direkter Parameter (applizierte Ladung, elektrische Feldstärke und Folientemperatur) auf die Oberflächenmodifizierung wurden bestimmt. Diese Untersuchungen zeigten, daß durch Photoeffekt abgelöste Elektronen die Hauptladungsträger und wesentliche Ursache der Oberflächenaktivierung sind. Die aktiven Spezies in der Oberfläche (vermutlich Radikale) fähren entweder zu Vernetzung und H-Abstraktion oder reagieren mit dem Entladungsgas. In der N2-Entladung können die Polymerradikale nur mit atomarem oder angeregtem Stickstoff reagieren, während sie in CO2 auch mit Molekeln im Grundzustand reagieren. Werden die Proben nach der Entladung mit Luft in Berührung gebracht, werden übriggebliebene Radikale durch Luftsauerstoff oxidiert. Zusätzlich wurde gefunden, daß eine UV-Strahlung in einer oberflächennahen Schicht aktiviert. Die Masse des Polymeren wird nicht durch die Corona-Entladung beeinflußt.
    Notes: Corona discharge treatment of isotactic polypropylene surfaces in N2 and CO2 was investigated by contact angle measurements and ESCA. The electrical characteristics of the discharges as well as the influence of indirect parameters (moment of air contact and ageing time) and direct parameters (applied charge, electrical field strength and film temperature) on the surface modification were determined. These investigations showed that electrons, emitted by photo effect are the dominant charge carriers and the main cause of surface activation. The active species in the surfaces (presumably radicals) can either perform crosslinking and H-abstraction or react with the discharge gas. In the N2-discharge the polymer radicals can only react with atomic or excited nitrogen whereas in CO2 they also react with ground state molecules. If the samples are brought into air contact after discharge leftover radicals are oxidized by atmospheric oxygen. In addition a UV-radiation causing activation in a surface layer was found. The bulk of the polymer is not influenced by corona discharge.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...