ISSN:
0197-8462
Keywords:
microwaves
;
amplitude modulation
;
murine allogeneic cytotoxicity
;
T lymphocytes
;
Life and Medical Sciences
;
Occupational Health and Environmental Toxicology
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Biology
,
Physics
Notes:
Significant inhibition of allogeneic cytotoxicity of the target cell MPC-11 by the murine cytotoxic T-lymphocyte line CTLL-1 was observed when the 4-h cytotoxicity assay was conducted in the presence of a 450-MHz field sinusoidally amplitude-modulated at 60 Hz. Exposure of the effector cells to the field prior to adding them to the target cells in the cytolytic assay resulted in a similar inhibition, suggesting a direct interaction of the field with the cytolytic T lymphocyte. The inhibition was preferentially expressed during the early allogeneic recognition phase. Fieldexposed cytolytic cells recovered their full cytolytic capacity in 12.5 h. A differential susceptibility was observed with modulation frequencies from 0 to 100 Hz. Peak suppression occurred at 60 Hz modulation, with progressively smaller effects at 40, 16, and 3 Hz. The unmodulated carrier wave did not affect the cytotoxicity. Effects with 80- and 100-Hz modulation were smaller than at 60 Hz. These results demonstrate an inhibitory but recoverable effect by certain amplitude modulations of weak nonionizing radiation upon the cell-mediated cytolytic immune response.
Additional Material:
2 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/bem.2250040308
Permalink