    Publication Date: 2004-12-03
    Description: The AVIRIS On-Board Calibrator (OBC) provides essential data for refining the calibration of each AVIRIS data run. Annual improvement to the AVIRIS sensor and laboratory calibration accuracy has resulted in increasingly high demands on the stability of the OBC. Since the 1995 flight season, the OBC could track the stability of the spectrometer alignment to the 2% level, a significant improvement over previous years. The major contributor to this 2% stability was the conversion from a constant-current bulb power supply to an intensity-based active feedback power supply. Given the high sensor signal-to-noise ratio, improving the OBC to track 1% or 0.5% changes was highly desirable. Achieving stability better than 2% required an examination of the mechanisms affecting stability.
    Keywords: Instrumentation and Photography
    Type: Summaries of the Seventh JPL Airborne Earth Science Workshop January 12-16, 1998; Volume 1; 105-110; JPL-Publ-97-21-Vol-1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2018-06-08
    Keywords: Earth Resources and Remote Sensing
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-08-16
    Description: Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.
    Keywords: Instrumentation and Photography
    Type: Proceedings of the Tenth JPL Airborne Earth Science Workshop; 193-203
    Format: text