ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1
    Publication Date: 2006-04-01
    Print ISSN: 0038-092X
    Electronic ISSN: 1471-1257
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Physics
    Published by Elsevier
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 1 (1991), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: The main airflow and contaminant paths or the spatial distribution of the age of air (or contaminant) in a room are of great interest in estimating venrilation efficiency. A simple meusurement method is presented which consists of injecting one or more tracer gases at locations of interest and analysing the concentration at several other locations, carefully chosen for best accuracy.Response functions can be fitted to these measurements, which are the age of the tracers or of the air or the concentration of the tracers as a function of the location. The salient paths, such as the dead zones, are also determined from these functions.The paper presents the method, its application and validation in a well controlled test room.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract A European project started at the end of 1992, in which, in addition to current methods, trained sensory panels were used to investigate office buildings all over Europe. The main aim of this EC-Audit was to develop assessment procedures and guidance on ventilation and source control, to help optimize energy use in buildings while assuring good indoor air quality.In each of nine countries, six or more office buildings were selected. Measurements were performed at five selected locations in each building. The buildings were studied while normally occupied and ventilated to identify the pollution sources in the spaces and to quantify the total pollution load caused by the occupants and their activities, as well as the ventilation systems. The investigation included physical and chemical measurements, assessment of the perceived air quality in the spaces by a trained sensory panel, and measurement of the outdoor air supply to the spaces. A questionnaire for evaluating retrospective and immediate symptoms and perceptions was given to the occupants of the buildings. The building characteristics were described by use of a check-list. The annual energy consumption of the buildings and the weather conditions were registered.This paper presents results and conclusions of the audit in 56 buildings in Europe. However, the analysis and discussions of the results are a summary of the work done, and are focused mainly on comparison between sensory assessments and the other measurements performed.Furthermore, this paper brings the results of the study based on a two-factor analysis. A paper dealing with results on a multifactorial analysis is in preparation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...