ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 186 (1960), S. 876-876 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] My paper, it is true, reports the failure of a mixture composed according to Shore's prescription, but it also states that xenon-oxygen fillings worked very well if a low oxygen content was chosen. Besides that, the paper says that no harm was done even by a continuous discharge, running for 1 hr. ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 140 (1955), S. 92-96 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Zusammenfassung Es wird experimentell gezeigt, daß sich die Betastrahlung eines Thalliumbleches, welches das aktive Isotop204Tl enthält, nicht ändert, wenn das Metall supraleitend wird. Daraus ist innerhalb der Meßgenauigkeit zu schließen, daß es im Innern eines Supraleiters keine stärkeren ungeordneten Magnetfelder als im Normalleiter gibt und daß die Mitwirkung der Atomelektronen bei der Absorption der Betateilchen ungeändert bleibt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 217 (1966), S. 1-6 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Rechenverfahren für die Isotopenspitzen im Massenspektrogramm einer beliebigen Verbindung wird abgeleitet und auf Beispiele angewandt. Das Verfahren ist übersichtlich und leicht erlernbar. Es erlaubt einen qualitativen Schluß auf die vorliegende Verbindung, wie er aus einer bloßen Angabe des Molgewichtes nicht gezogen werden kann.
    Notes: Summary A method for the calculation of isotopic peak heights in a mass spectrogram of any compound is derived and applied to examples. The method is clearly established and easily comprehensible. It permits qualitative conclusions of the compound in question, an information that is not obtainable merely from the molecular weight.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 166 (1959), S. 433-439 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A universally usable, quantitative assay for deuterium-labeling work demands a stoichiometrical transformation of all samples into elementary hydrogen. For the detector, it is the best to connect directly a fractometer, that works with a catharometer cell. Tests with several carrier gases and an attempt with a palladium-black column failed; a molecular sieve with ordinary hydrogen as carrier was appropriate. The fractogram, written by a compensograph, shows a well gaugeable peak which is linearly proportional to the deuterium content of the sample. The error at full deflection amounts to ±0,5%. Protium deuteride, HD, is acting as if it were 1/2 D2, a fact that was confirmed by mass-spectrometric measurements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 201 (1964), S. 253-262 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A cryoscopic apparatus for the purity assay of fusible, mostly organic samples was built afterSmit. It works in the half-micro scale above 99 mole%, where the absolute value of the purity will lie within ±0.05 mole%. The sample, which is always kept under streaming nitrogen, surrounds as a thin layer a platinum resistance thermometer that stands in the center of an electrically heated aluminium cylinder. A constant supply of heat is ensured by controlling the temperature difference against a second thermometer of the same kind, which is inserted near the heated periphery of the cylinder. It is not necessary to calibrate the thermometers. Control is mediated by a double Wheatstone bridge, the one output of which acts on the recording device, the other on the heater. The graphical evaluation of the records derives from the two-phase diagram solid-liquid. As a referential instance, a second sample has to be measured, which is obtained from the specimen through artificial contamination by a known amount.
    Notes: Zusammenfassung Zur Reinheitsbestimmung schmelzbarer, vorwiegend organischer Proben wurde eine kryoskopische Apparatur nachSmit gebaut. Sie arbeitet oberhalb 99 Mol-% im Halbmikrobereich, wobei der Absolutwert der Reinheit auf ±0,05 Mol-% genau meßbar ist. Die Probe, die ständig unter strömendem Stickstoff gehalten wird, umgibt als dünne Schicht ein Platin-Widerstandsthermometer, das sich in der Mitte eines elektrisch geheizten Aluminiumzylinders befindet. Konstanz der Wärmezufuhr wird gesichert durch Regelung der Temperaturdifferenz gegen ein gleichartiges zweites Thermometer, das dicht am geheizten Zylindermantel eingesteckt ist. Die Thermometer brauchen nicht geeicht zu werden. Die Regelung wird durch eine Doppel-Wheatstonebrücke vermittelt, deren einer Ausgang auf den Schreiber und deren anderer auf die Heizung wirkt. Die graphische Auswertung ist aus dem Zweiphasen-Diagramm fest-flüssig abgeleitet. Als Bezugsstandard ist eine zweite Probe zu messen, die man durch Verunreinigung der ursprünglichen Substanz um einen bekannten Betrag erhält.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 179 (1961), S. 93-98 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The experience in this laboratory since 1955 is strongly in favor to the counting of any 14-C sample in the gas phase in the form of CO2, although a more thoroughly contrived gas-analytical apparatus and a more elaborate electronic set are required. As compared with barium-carbonate or even gas GM-counting, this method offers the advantage of a consistent, dependable, and highly efficient procedure. The samples are burned in a Liebig tube, the carbon dioxide is condensed into a high-vacuum and gas-mixing line. The CO2 content of the counter is 20%, the remainder being methane only; the plateau extends from 2800 to 3050 volts. The absolute efficiency may be chosen between 83 and 89%, the linear proportionality of activity and rate is granted up to 15000 cpm. The good counter characteristic is fettered to the quality of the amplifier. The pertinence of a separate and mutually independent control of the different amplification parameters is explained. A graphical scheme demonstrates the electronic treatment of the original pulse-mountains by differentiation, integration, discrimination, choice of paralysis time, and pulse shaping.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 71 (1959), S. 439-439 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 67 (1955), S. 643-648 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Für die Genauigkeit der Ergebnisse radiometrischer Analysen sind neben Wäge- und Pipettierfehlern vor allem die endliche Dauer der Zählzeiten und die Unschärfe der Aktivitätseichung wesentlich. Es wird gezeigt, wie sich die Eichdaten möglichst genau und doch einfach gewinnen lassen. Der Einfluß aller Fehlermöglichkeiten wird nach der Gaußschen Methode der Fehlerrechnung verfolgt. Sämtliche zur Berechung des „Mittleren Fehlers“ eines Analysenergebnisses nötigen Formeln sind angegeben; erläutert wird das Verfahren an speziellen Beispielen. Durch Kontrollanalyse wird gezeigt, daß die Befunde auf wenige Prozente genau sind.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 37 (1965), S. 418-422 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Die Geschwindigkeit von Feststoffteilchen bei der pneumatischen Förderung oder von Katalysatoren und Wärmeträgern, die in chemischen Anlagen im Kreislauf geführt werden, läßt sich unter ungestörten Betriebsverhältnissen sehr genau messen, wenn einige Teilchen radioaktiv sind. Für die Markierung von keramischem Material eignet sich besonders das Nuclid 140La, das eine harte γ-Strahlung aussendet und eine Halbwertszeit von nur 40,2 h besitzt. Es wird durch Bruttoaktivierung von Lanthan durch Neutronen-Bestrahlung gewonnen. Die Strahlenschutzmaßnahmen sind relativ gering, wenn die Aufenthaltszeiten des Personals auf das Notwendigste beschränkt werden.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 31 (1959), S. 318-323 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Das neue Markierungsverfahren wird erläutert am Beispiel der Geschwindigkeitsmessung von Wärmeträgerpartikeln, in einer Wanderschichtanlage. Der sonst übliche Weg, die markierten Körper mittels zuvor beschaffter Radionuklide herzustellen, ist hier oft nicht gangbar. Infolge ihrer gemischten Zusammensetzung lassen sich aber gewöhnliche, dem Vorrat entnommene Teilchen mit den Neutronen eines Kernreaktors „bruttoaktivieren“. Diese γ-strahlenden Probekörper, deren Zahl mehrere Hundert betragen kann, ermöglichen in kurzer Zeit zahlreiche Messungen unter Betriebsbedingungen.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...