ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 807-812 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high-sensitivity, laser-excited, confocal-fluorescence scanner has been developed for the detection of fluorescently labeled nucleic acids separated on slab gels. The gel is placed on a motor-driven, two-dimensional scan stage and raster scanned past the optical detection system. The 488-nm argon ion laser beam is introduced into the confocal optical system at a long-pass dichroic beam splitter and focused within the gel to an ∼2 μm diameter spot by a high-numerical aperture microscope objective. The resulting fluorescence is gathered by the objective, passed back through the first long-pass beam splitter, and relayed to a second dichroic beam splitter that separates the red and green emissions. The fluorescence is then focused on confocal spatial filters to reduce stray and scattered light, passed through spectral filters, and detected with photomultipliers. The resulting signals are amplified, filtered, and digitized for display on a computer. This system can detect as little as 5×10−12 M fluorescein, the resolution as operated is 160 μm, and it can scan a 6 cm×6 cm gel using a scan rate of 4 cm/s in 12 min. The detection of DNA on slab gels, two-color DNA fragment sizing, and microtiter plate scanning are presented to illustrate some of the possible applications of this apparatus.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 91 (1989), S. 3477-3482 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Tert-butyl bromide is photodissociated at 277.3 nm (in the tail of the first absorption continuum). Both fragments, i.e., the t-butyl radical and the Br(2P1/2) atom, are detected by laser MPI-TOF mass spectrometry. Seeded, supersonic beams of this pseudosymmetric top molecule are readily focusable and orientable (via its first-order Stark effect) using the electrostatic hexapole lens. The linearly polarized laser-induced photofragmentation technique reveals unusually high degrees of orientation, significantly greater than that for t-C4H9I, due to the less serious hyperfine disorientation effect for the Br- (vs I-) containing molecule. Thus t-C4H9Br is an excellent candidate reagent for reactive asymmetry scattering studies of the steric effect via the oriented molecule beam method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 64 (1992), S. 967-972 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 64 (1992), S. 2138-2142 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 90 (1986), S. 219-222 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 92 (1988), S. 5436-5438 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Uncrosslinked polyacrylamide solutions ; DNA sequencing resolution ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Two preparations of linear polyacrylamide with average molecular weights of 0.37 million and 1.14 million Da, and a deuterated preparation with an average molecular weight of 1.71 million Da, were used to study the effects of molecular weight, polydispersity, and concentration on the mesh size of entangled polymers in a DNA sequencing buffer solution and their ability to resolve DNA sequencing reactions by capillary electrophoresis. The polyacrylamide concentrations were above the overlap threshold C*, the concentration above which an entangled polymer network is expected to form. Small angle neutron scattering experiments showed that between 1% and 8% polyacrylamide, the mesh size (ζ) can be expressed by the relation ζ = 2.09C-0.76, where ζ is in Å and C is the polymer concentration in g/mL. The mesh size depended only on the concentration and was independent of the average molecular weight of the polyacrylamide. Consistent with this result, electrophoretic mobilities of DNA moving through the polymer network depended almost entirely on the polyacrylamide concentration and not on its molecular weight or polydispersity. Although separation was little affected, band sharpness persisted to longer DNAs when the polymer network contained a higher fraction of larger polyacrylamide molecuels. We postulate a dispersive effect that depends on the size of the DNA and the resiliency of the polymer network. This interpretation provides a rationale for optimizing the design of polymer solutions to sieve DNA for sequencing by capillary electrophoresis.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 1841-1851 
    ISSN: 0173-0835
    Keywords: Multi-capillary electrophoresis ; DNA sequencing ; Fiberoptics ; Spectral detection ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: An 8-capillary prototype electrophoresis system for DNA sequencing has been construted. The sequence of 400-450 bases can be obtained from each capillary in less than an hour form sequencing reactions generated with four-color fluorescent terminators. Illumination of each capillary and collection of fluorescence is through individual optical fibers. Resolution of the DNA ladder is through a replaceable sieving matrix of linear polyacrylamide in reusable coated capillaries. Light from an argon ion laser is introduced into a fused biconically tapered fiber-optic splitter, and individual fibers deliver approximately 10 mW of 514 nm light to each of the eight electrophoresis capillaries. Illumination and collection are by fibers normal to the surface of the electrophoresis capillary and at right angle to each other. Illumination by a fiber with low numerical aperture and collection by a fiber with high numerical aperture provides good sensitivity and signal-to-noise ratios without the need for microlenses (limit of detection: 1.5 × 10-11 M fluorescein analog dye with a signal-to-noise ratio of 2). The eight collection fibers are passed in parallel through holographic filters for Rayleigh rejection and into an imaging spectrograph, which simultaneously displays the full fluorsecence spectrum (475-648 nm) from the eight capillaries in parallel on the surface of an intensified chargecoupled device (CCD). The CCD is read out at a rate of 3.4 complete images per second.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 1415-1427 
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; DNA sequencing ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Cylindrial capillaries can be used as optical elements in a waveguide, where refraction will confine an appropriately focused light beam to pass through the interiors of successive capillaries in a flat parallel array. Such a capillary waveguide allows efficient illumination of samples in multiple capillaries with relatively little laser power. Analytical expressions derived under paraxial and thin-lens approximations provide guidance in selecting the capillary sizes and the refractive indices that will produce the waveguiding effect, but accurate predictions require exact ray tracing. Small reflective losses as the light passes through the capillary surfaces cause cumulative intensity decreases, but the resulting lack of uniformity can be compensated to a considerable extent by illuminating the capillary array from both sides. A 12-capillary waveguide illuminated from both sides in air has a difference of less than 10% from the strongest to the weakest illumination. By increasing the refractive index of both the external medium and the contents of the capillaries, a 96-capillary waveguide for DNA sequencing could be produced that would also provide nearly uniform illumination. A 12-capillary, bi-directionally illuminated waveguide system for DNA sequencing has been constructed. The two focused laser beams are delivered by integrated fiber optic transmitters (IFOTs), and fluorescence is collected by a set of optical fibers whose spacing exactly matches that of the capillaries in the waveguide. The system is easy to align and provides sensitive detection of fluorescence with minimal cross-talk between channels.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 1994-04-01
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...