ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Keywords
Publisher
Years
  • 1
    Publication Date: 2024-06-25
    Description: Offshore wind energy is a steadily growing sector contributing to the worldwide energy production. The impact of these offshore constructions on the marine environment, however, remains unclear in many aspects. In fact, little is known about potential emissions from corrosion protection systems such as organic coatings or galvanic anodes composed of Al and Zn alloys, used to protect offshore structures. In order to assess potential chemical emissions from offshore wind farms and their impact on the marine environment water and sediment samples were taken in the surrounding and within different wind farms of the German Bight in April 2018 within the context of the Hereon-BSH project OffChEm. The surface sediment samples were taken by a box grab, homogenized, freeze-dried and wet-sieved to gain the 〈20 µm grain size fraction. The 〈20 µm grain size fraction was acid digested and measured by ICP-MS/MS for their (trace) metal mass fractions. The Sr and Pb isotope ratios were measured by MC ICP-MS after an automated matrix separation with a prepFAST MC system.
    Keywords: Aluminium; Aluminium, limit of detection; Aluminium, limit of quantification; Aluminium, uncertainty; Antimony; Antimony, limit of detection; Antimony, limit of quantification; Antimony, uncertainty; Arsenic; Arsenic, limit of detection; Arsenic, limit of quantification; Arsenic, uncertainty; AT261; Atair; Atair261; Atair261_10_BC; Atair261_11_BC; Atair261_13_BC; Atair261_14_BC; Atair261_15_BC; Atair261_16_BC; Atair261_17_BC; Atair261_2_BC; Atair261_20_BC; Atair261_21_BC; Atair261_22_BC; Atair261_23_BC; Atair261_24_BC; Atair261_25_BC; Atair261_27_BC; Atair261_29_BC; Atair261_3_BC; Atair261_30_BC; Atair261_31_BC; Atair261_32_BC; Atair261_33_BC; Atair261_34_BC; Atair261_35_BC; Atair261_36_BC; Atair261_37_BC; Atair261_38_BC; Atair261_39_BC; Atair261_4_BC; Atair261_40_BC; Atair261_41_BC; Atair261_42_BC; Atair261_43_BC; Atair261_44_BC; Atair261_46_BC; Atair261_47_BC; Atair261_48_BC; Atair261_49_BC; Atair261_50_BC; Atair261_51_BC; Atair261_52_BC; Atair261_53_BC; Atair261_54_BC; Atair261_55_BC; Atair261_56_BC; Atair261_57_BC; Atair261_58_BC; Atair261_59_BC; Atair261_60_BC; Atair261_61_BC; Atair261_62_BC; Atair261_63_BC; Atair261_9_BC; Barium; Barium, limit of detection; Barium, limit of quantification; Barium, uncertainty; BC; Beryllium; Beryllium, limit of detection; Beryllium, limit of quantification; Beryllium, uncertainty; Bismuth; Bismuth, limit of detection; Bismuth, limit of quantification; Bismuth, uncertainty; Box corer; Cadmium; Cadmium, limit of detection; Cadmium, limit of quantification; Cadmium, uncertainty; Caesium; Caesium, limit of detection; Caesium, limit of quantification; Caesium, uncertainty; Calcium; Calcium, limit of detection; Calcium, limit of quantification; Calcium, uncertainty; Cerium; Cerium, limit of detection; Cerium, limit of quantification; Cerium, uncertainty; Chromium; Chromium, limit of detection; Chromium, limit of quantification; Chromium, uncertainty; Cobalt; Cobalt, limit of detection; Cobalt, limit of quantification; Cobalt, uncertainty; DATE/TIME; DEPTH, sediment/rock; Dysprosium; Dysprosium, limit of detection; Dysprosium, limit of quantification; Dysprosium, uncertainty; Element analysis grain size fraction 〈 20 microns via ICP-MS (total digest); ELEVATION; Erbium; Erbium, limit of detection; Erbium, limit of quantification; Erbium, uncertainty; Europium; Europium, limit of detection; Europium, limit of quantification; Europium, uncertainty; Event label; Gadolinium; Gadolinium, limit of detection; Gadolinium, limit of quantification; Gadolinium, uncertainty; Gallium; Gallium, limit of detection; Gallium, limit of quantification; Gallium, uncertainty; German Bight; Helmholtz-Zentrum Hereon; Hereon; Holmium; Holmium, limit of detection; Holmium, limit of quantification; Holmium, uncertainty; Indium; Indium, limit of detection; Indium, limit of quantification; Indium, uncertainty; Iron; Iron, limit of detection; Iron, limit of quantification; Iron, uncertainty; Lanthanum; Lanthanum, limit of detection; Lanthanum, limit of quantification; Lanthanum, uncertainty; LATITUDE; Lead; Lead, limit of detection; Lead, limit of quantification; Lead, uncertainty; Lead-206/Lead-204 ratio; Lead-206/Lead-204 ratio, uncertainty; Lead-207/Lead-204 ratio; Lead-207/Lead-204 ratio, uncertainty; Lead-207/Lead-206, uncertainty; Lead-207/Lead-206 ratio; Lead-208/Lead-204 ratio; Lead-208/Lead-204 ratio, uncertainty; Lead-208/Lead-206 ratio; Lead-208/Lead-206 ratio, uncertainty; Lead-208/Lead-207 ratio; Lead-208/Lead-207 ratio, uncertainty; Lithium; Lithium, limit of detection; Lithium, limit of quantification; Lithium, uncertainty; LONGITUDE; Lutetium; Lutetium, limit of detection; Lutetium, limit of quantification; Lutetium, uncertainty; Magnesium; Magnesium, limit of detection; Magnesium, limit of quantification; Magnesium, uncertainty; Manganese; Manganese, limit of detection; Manganese, limit of quantification; Manganese, uncertainty; Molybdenum; Molybdenum, limit of detection; Molybdenum, limit of quantification; Molybdenum, uncertainty; Multi-collector ICP-MS (MC-ICP-MS), Nu Plasma II, Wrexham, UK; External intra-elemental calibration using NIST SRM 981; Multi-collector ICP-MS (MC-ICP-MS), Nu Plasma II, Wrexham, UK; External intra-elemental calibration using NIST SRM 987; Neodymium; Neodymium, limit of detection; Neodymium, limit of quantification; Neodymium, uncertainty; Nickel; Nickel, limit of detection; Nickel, limit of quantification; Nickel, uncertainty; Potassium; Potassium, limit of detection; Potassium, limit of quantification; Potassium, uncertainty; Praseodymium; Praseodymium, limit of detection; Praseodymium, limit of quantification; Praseodymium, uncertainty; Rubidium; Rubidium, limit of detection; Rubidium, limit of quantification; Rubidium, uncertainty; Samarium; Samarium, limit of detection; Samarium, limit of quantification; Samarium, uncertainty; Sample ID; Sample method; Scandium; Scandium, limit of detection; Scandium, limit of quantification; Scandium, uncertainty; Silver; Silver, limit of detection; Silver, limit of quantification; Silver, uncertainty; Station_10_HELW3; Station_11_NOST1; Station_13_NOST3; Station_14_NOST4; Station_15_NOST5; Station_16_NOST6; Station_17_NOST7; Station_2_TI7; Station_20_AMWE2; Station_21_AMWE3; Station_22_AMWE4; Station_23_AMWE5; Station_24_AMWE6; Station_25_AMWE7; Station_27_AMWE9; Station_29_DOLW1; Station_3_MEWI1; Station_30_DOLW2; Station_31_DOLW3; Station_32_BKRI1; Station_33_BKRI2; Station_34_BKRI3; Station_35_BKRI4; Station_36_BKRI5; Station_37_ALVE2; Station_38_ALVE3; Station_39_ALVE1; Station_4_MEWI3; Station_40_ALVE4; Station_41_DOLW5; Station_42_DOLW6; Station_43_GOWI2; Station_44_GOWI3; Station_46_GOWI6; Station_47_GOWI7; Station_48_GOWI8; Station_49_GOWI9; Station_50_GOWI1; Station_51_GOWI4; Station_52_GOWI10; Station_53_GOWI11; Station_54_GOWI20; Station_55_GOWI21; Station_56_GOWI22; Station_57_GOWI23; Station_58_GOWI24; Station_59_GOWI25; Station_60_GOWI26; Station_61_GOWI27; Station_62_GOWI28; Station_63_GOWI29; Station_9_HELW2; Station label; Strontium; Strontium, limit of detection; Strontium, limit of quantification; Strontium, uncertainty; Strontium-87/Strontium-86 ratio; Strontium-87/Strontium-86 ratio, uncertainty; Terbium; Terbium, limit of detection; Terbium, limit of quantification; Terbium, uncertainty; Thallium; Thallium, limit of detection; Thallium, limit of quantification; Thallium, uncertainty; Thulium; Thulium, limit of detection; Thulium, limit of quantification; Thulium, uncertainty; Titanium; Titanium, limit of detection; Titanium, limit of quantification; Titanium, uncertainty; Tungsten; Tungsten, limit of detection; Tungsten, limit of quantification; Tungsten, uncertainty; Uranium; Uranium, limit of detection; Uranium, limit of quantification; Uranium, uncertainty; Vanadium; Vanadium, limit of detection; Vanadium, limit of quantification; Vanadium, uncertainty; Ytterbium; Ytterbium, limit of detection; Ytterbium, limit of quantification; Ytterbium, uncertainty; Zinc; Zinc, limit of detection; Zinc, limit of quantification; Zinc, uncertainty
    Type: Dataset
    Format: text/tab-separated-values, 9992 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...