ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-675X
    Keywords: 7A6-antigen ; Annexin V ; apoptosis ; DNA fragmentation ; phosphatidyl serine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract The objective of this study was to investigate the sensitivity, specificity and reproducibility of some frequently used apoptosis assays. The degree of apoptosis was tested in two T-lymphoblastoid cell lines, HSB and Jurkat, in which apoptosis was induced by ionizing radiation. HSB and Jurkat samples were taken before, and 0, 2, 4, 6, 8 and 24 h after irradiation with 6 and 10 Gray, or with 10 and 14 Gray, respectively. Four frequently used flow cytometric techniques were evaluated: (i) Annexin V/Propidium Iodide assay, detecting the translocation of phosphatidylserine to the outer leaflet of the plasma membrane, simultaneously with preservation of the membrane integrity; (ii) Terminal deoxynucleotidyl Transferase (TdT) Uridine triphosphate (UTP) nick end labelling (TUNEL), revealing the presence of DNA strand breaks; (iii) DNA-flow cytometry, measuring DNA-stainability (DNA-fragmentation assay) and (iv) Phycoerythrin-labelled (PE) Apo2.7-assay, a monoclonal antibody against 7A6 antigen, a protein, which becomes exposed upon the mitochondrial membrane during apoptosis. As a general standard for identifying that apoptosis had occurred, the cells were assessed for the presence of DNA-laddering on agar gel electrophoresis and by demonstration of characteristic cell morphology. Results were as follows: Fluorescein Isothiocyanate (FITC)-labelled Annexin V/Propidium iodide flow cytometry appeared to be the most sensitive, the most specific and the most user-friendly test for measurement of apoptosis of cells in culture conditions in suspension. The expression of 7A6 antigen on the mitochondrial membrane appeared to be not specific for apoptotic cell death.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-675X
    Keywords: Annexin V ; apoptosis ; flow cytometry ; intracellular Ca2+ ; intracellular pH ; mitochondrial membrane potential.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract The sequential occurrence of plasma and mitochondrial membrane alterations, intra-cellular pH shifts and changes in intracellular Ca2+ concentration after induction of cell death was monitored by flow cytometry in Jurkat and HSB2-cells. Cell death was induced by treatment with anti-Fas antibodies or by irradiation. Phosphatidylserine (PS) exposure and plasma membrane integrity were measured with FITC-Annexin V adhesion and by Propidium Iodide exclusion. Transition of the mitochondrial membrane potential was monitored by the occurrence of decay of DiOC6 fluorescence. Intracellular pH shifts were monitored by changes in the ratio of fluorescence at 575 nm and at 635 nm of SNARF-1-AM. Fluctuations in intracellular Ca2+ concentration were established by changes in Fura red quenching. The Jurkat cells were sensitive to anti-Fas treatment, while HSB-2 cells were not. HSB-2 cells appeared more sensitive to radiation damage than Jurkat cells. In all experiments the transition of mitochondrial membrane potential occurred first, almost immediately followed by PS exposure. Fluctuations in intracellular Ca2+ concentration occurred later and were less outspoken. A decrease in intracellular pH occurred not earlier than 24 hours after anti-Fas treatment. Chelation of intracellular Ca2+ concentration with BAPTA-AM had no effect on the time sequence of cell death related events.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...