ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 13 (1978), S. 1127-1130 
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 15 (1977), S. 228-232 
    ISSN: 1741-0444
    Keywords: Electrocardiography ; Haemodynamics ; Resistance of skin ; Transducers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire On décrit un transducteur à plusieurs fonctions pour l'affichage numérique du photo-électroarteriographe, de la réponse en terme de résistance de la peau et de l'électrocardiogramme. Le rôle joué par la constante de temps en photo-électroartériographie est présenté et discuté. Des enregistrements chiffrés simultanés provenant au photo-électroartériographe du pouls et des changements vaso-moteurs ont été obténus par couplage direct et avec diverses constantes de temps. D'après les résultats, on constate seulement par rapport aux enregistrements réalisés par couplage direct, une perte de 5% en amplitude en ce qui concerne le pouls, et une perte de 25% en amplitude pour la réponse vaso-motrice lorsque la constante de temps est de 3 s. Une constante de temps de 25 s entraîne une perte de 5% seulement de l'amplitude vaso-motrice et une reproduction fidèle du pouls. De façon évidente, la reproduction la plus nette des changements vaso-moteurs apparaît avec l'enregistrement en couplage direct. Bien que l'usage d'une constante de temps de 3 s empêche une reproduction fidèle de la réponse vaso-motrice, elle permet d'identifier les variations du pouls. On recommande aux chercheurs intéressés à la fois par les variations du pouls et par ceux d'origine vaso-motrice, de se servir de canaux d'enregistrements séparés et d'appliquer des constantes de temps de 3 secondes et un canal d'enregistrement couplage direct. Si on ne peut pas utiliser le couplage direct pour l'enregistrement des réponses vaso-motrices, une constante de temps supérieure à 25 s est nécessaire.
    Abstract: Zusammenfassung Ein Mehrfunktionsmeßwandler zum Erzielen des digitalen Photoplethysmogramms, der Hautwiderstandsreaktion und des Elektrokardiogramms wird beschrieben. Die Bedeutung der Zeitkonstanten in der Photoplethysmografie wird dargestellt und besprochen. Es wurden gleichzeitig digitale photoplethysmografische Aufzeichnungen des pulsierenden Volumens (PV) und der vasomotorischen Änderungen (VM) durch Verwendung einer Direktkupplung (DC) und verschiedener Zeitkonstanten erzielt. Die Ergebnisse weisen darauf hin, daß im Vergleich zu DC-Aufzeichnungen im PV nur ein Amplitudenverlust von 5% auftritt und im Frequenzgang, der mit einer Zeitkonstanten von 3 Sekunden registriert wird, ein Ämplitudenverlust von 25%. Bei einer Zeitkonstanten von 25 Sekunden ergibt sich nur ein 5% iger Verlust in der VM-Ämplitude und eine getreue Wiedergabe des PV. Die genaueste Wiedergabe der VM-Änderungen tritt offensichtlich bei einer DC-Aufzeichnung auf. Obgleich die Verwendung einer Zeitkonstanten von 3 Sekunden keine getreue Wiedergabe des VM-Frequenzganges verhindert, gestattet sie die Feststellung von Änderungen im PV. Es wird empfohlen, daß Untersucher, die an PV- und VM-Änderungen interessiert sind, getrennte Registrierkanäle mit Zeitkonstanten von 3 Sekunden verwenden und einen mit Direktkoppelung. Wenn eine Direktkoppelung zur Aufzeichnung von vasomotorischen Reaktionen verwendet werden kann, ist eine Zeitkonstante von über 25 Sekunden erforderlich.
    Notes: Abstract A multifunction transducer for obtaining the digital photoplethysmogram, skin-resistance response and electrocardiogram is described. The importance of the time constant in photoplethysmography is illustrated and discussed. Simultaneous digital photoplethysmographic recordings of the pulsatile volume and vasomotor changes were obtained using direct coupling and various time constants. Results indicate that, when compared to direct-coupled recordings, only a 5% loss in amplitude occurs in the pulsatile volume and a 25% loss in the amplitude of the vasomotor response recorded with a 3 s time constant. A 25 s time constant results in only a 5% loss in the vasomotor amplitude and a faithful reproduction of pulsatile volume. Obviously, the clearest reproduction of vasomotor change occurs with a direct-coupled recording. Although the use of a 3 s time constant prevents faithful reproduction of the vasomotor response, it permits the identification of changes in pulsatile volume. It is recommended that investigators interested in both pulsatile-volume and vasomotor changes use separate recording channels with time constants of 3 s and one with direct coupling. If direct coupling cannot be used for recording vasomotor responses, a time constant in excess of 25 s is required.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 7 (1969), S. 49-56 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire L'impédance à basse fréquence d'une électrode d'argent pur, plongée dans du sérum physiologique, présente une réactance capacitive, alors qu'elle devient résistive après dépôt de chlorure. Il a été montré qu'un dépôt de chlorure de 100 à 500 mA. sec/cm2 présente l'impédance électrode-électrolyte la plus faible. Au-delà de cette valeur, l'impédance croît à toutes les fréquences, mais sa partie résistive reste inchangée. Pour obtenir un dépôt de chlorure proportionnel au courant produit et au temps écoulé, on a montré que la densité du courant minimum doit être de l'ordre de 5 mA/cm2 d'électrode.
    Abstract: Zusammenfassung Die Niederfrequenzimpedanz reiner Silberelektroden im Kontakt mit physiologischer Kochsalzlösung zeigte kapazitiven Widerstand. Nach Chloridablagerung wurde die Impedanz resistiv. Die Messungen ergaben bei einer Chloridschicht von 100–500 mA.sec/cm2 Elektrodenfläche die niedrigste Elektroden-Elektrolyt-Impedanz. Eine Verlängerung der Chloridierung über diesen Bereich erhöhte die Elektroden-Elektrolyt-Impedanz bei allen Frequenzen, änderte jedoch nicht die resistive Natur der Impedanz. Um eine Chloridschicht zu erhalten, welche dem Produkt von Milliampere und Sekunden proportional ist, muß nach unseren Messungen eine minimale Chloridierungsstromstärke von 5 mA/cm2 Elektrodenfläche eingesetzt werden.
    Notes: Abstract The low frequency impedance of bare silver electrodes in contact with physiological saline was found to exhibit capacitive reactance and by the deposition of chloride the impedance became resistive in nature. It was found that a chloride deposit of 100–500 mA.sec/cm2 of electrode area provided the lowest electrode-electrolyte impedance. Prolongation of chloriding beyond this range increased the electrode-electrolyte impedance at all frequencies but did not alter the resistive nature of the impedance. To achieve a chloride deposit which is proportional to the product of mA and sec it was found that a minimum chloriding current density of 5 mA/cm2 of electrode area should be used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 7 (1969), S. 289-296 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Des expériences ont été réalisées aussi bien chez l'homme que chez le chien afin de déterminer les niveaux de courant alternatif sinusoïdaux qui peuvent être appliqués sans danger à travers le thorax. Le seuil de sensibilité au courant a été déterminé dans la gamme de fréquences de 20 Hz à 20 kHz au moyen de deux dispositions différentes d'électrodes sur huit sujets adultes normaux masculins. Les seuils de stimulation du pneumogastrique et defibrillation ventriculaire dans la gamme de fréquences de 20 Hz à 3 kHz ont été déterminés chez le chien à l'aide des mêmes dispositions d'électrodes; les résultats obtenus pour la fibrillation ont été extrapolés de façon à estimer leurs niveaux correspondants chez l'homme. Les résultats indiquent que les valeurs des seuils de courant qui produisent ces phénomènes augmentent avec la fréquence. Ainsi des courants ayant une fréquence supérieure à 5 kHz sont recommandés pour les mesures par impédance des phénomènes physiologiques.
    Abstract: Zusammenfassung Beim Menschen und beim Hund wurden Experimente durchgeführt, um die sicheren Größen sinusförmigen Wechselstroms zu bestimmen, welche durch den Thorax geschickt werden können. Die Empfindungsschwelle des Stromes wurde über einen Frequenzbereich von 20 Hz bis 20 kHz bei acht normalen männlichen Erwachsenen bei zwei verschiedenen Elektrodenanordnungen bestimmt. Die Schwelle der Vagusreizung und des Kammerflimmerns im Frequenzbereich von 20 Hz bis 3 kHz wurde am Hund bei denselben Elektrodenanordnungen bestimmt. Die Ergebnisse für das Kammerflimmern wurden zur Schätzung vergleichbarer Stromstärken am Menschen herangezogen. Die Resultate zeigen, daß die Höhe der Stromstärkenschwelle zum Erreichen dieser Phänomene mit steigender Frequenz ansteigt. Stromstärken von mehr als 5 kHz werden zur Messung physiologischer Vorgänge mit elektrischen Impedanzmethoden vorgeschlagen.
    Notes: Abstract Experiments were conducted in man and the dog to determine the safe levels of sinusoidal alternating current which can be passed through the thorax. The sensation current threshold was determined over a frequency range of 20 Hz to 20 kHz in 8 normal adult males for two different electrode arrangements. The thresholds for vagal stimulation and ventricular fibrillation in the frequency range of 20 Hz to 3 kHz were determined in the dog for the same electrode arrangements, and the data obtained for fibrillation was extrapolated to estimate the comparable levels for man. The results indicate that the magnitudes of the current thresholds to produce these phenomena increase with an increase in frequency. Currents higher than 5 kHz in frequency are recommended for the measurement of physiological events by electrical impedance techniques.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
  • 6
    Publication Date: 1978-05-01
    Print ISSN: 0022-2461
    Electronic ISSN: 1573-4803
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2012-12-19
    Description: The adjoints of the GEOS-Chem Chemical Transport Model and a comprehensive cloud droplet parameterization are coupled to study the sensitivity of cloud droplet number concentration (Nd) over US regions and Central Europe to global emissions of anthropogenic fine mode aerosol precursors. Simulations reveal that the Nd over the midwestern and southeastern US is mostly sensitive to SO2 emissions during August, and to NH3 emissions during February. Over the western US, Nd is mostly sensitivity to SO2 and primary organic aerosol emissions. In Central Europe, Nd is most sensitive to NH3 and NOx emissions. As expected, local emissions strongly affect Nd; long-range transport, however, is also important for the western US and Europe. Emissions changes projected for the year 2050 are estimated to have the largest impacts on cloud albedo and Nd over Central Europe during August (42% and 82% change, respectively) and western US during February (12% and 36.5% change, respectively).
    Print ISSN: 0094-8276
    Electronic ISSN: 1944-8007
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2013-01-05
    Description: [1]  The adjoints of the GEOS-Chem Chemical Transport Model and a comprehensive cloud droplet parameterization are coupled to study the sensitivity of cloud droplet number concentration ( N d ) over US regions and Central Europe to global emissions of anthropogenic fine mode aerosol precursors. Simulations reveal that the N d over the midwestern and southeastern US is mostly sensitive to SO 2 emissions during August, and to NH 3 emissions during February. Over the western US, N d is mostly sensitivity to SO 2 and primary organic aerosol emissions. In Central Europe, N d is most sensitive to NH 3 and NO x emissions. As expected, local emissions strongly affect N d ; long-range transport, however, is also important for the western US and Europe. Emissions changes projected for the year 2050 are estimated to have the largest impacts on cloud albedo and N d over Central Europe during August (42% and 82% change, respectively) and western US during February (12% and 36.5% change, respectively).
    Print ISSN: 0094-8276
    Electronic ISSN: 1944-8007
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...