Publication Date:
2013-07-04
Description:
Many investigations have been published on the transferability of RF immunity test results between system and IC-levels. The RF signal level at DUT (Device under Test) inputs, i.e. either RF voltage amplitude or RF input current, is used as a reference value for the load on the DUT. Existing approaches analyze the DUT response as a function of the RF signal level at a single input pin, e.g. supply voltage. Sufficient accuracy of such an approach could be shown in several cases, but results are not sufficient as a general solution for complex DUT. This paper proposes both theoretical analysis and practical implementation of a DPI setup, where a disturbance, equivalent to system-level BCI setup, can be delivered to multiple DUT input ports.
Print ISSN:
1684-9965
Electronic ISSN:
1684-9973
Topics:
Electrical Engineering, Measurement and Control Technology
Permalink