Rate-of-discharge curves that show the discharge characteristics of an injection system having a very short fuel passage are presented. The rate of discharge closely follows the rate of displacement of the injection-pump plunger for open nozzles in which the maximum calculated pressures at the orifice do not exceed a certain value, which is dependent on the particular injection pump. With small orifices and high pump speeds, the rate of discharge does not follow the rate of plunger displacement because the higher discharge pressure results in increased leakage with corresponding decrease in discharge rate. The rate of discharge is not directly related to the rate of plunger displacement with automatic injection valves having closed nozzles. The types of pump check valve tested did not control the rate of cut-off or the discharge rate but they did affect the injection lag. Use of the short fuel passage eliminated the formation of secondary discharges.