ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    In:  Geophys. Prospecting, Basel, Inst. f. Geophys., Ruhr-Univ. Bochum, vol. 24, no. 5, pp. 756-772, pp. L14310, (ISSN: 1340-4202)
    Publication Date: 1976
    Keywords: Instruments ; Radiation pattern ; Applied geophysics ; Seismics (controlled source seismology) ; FROTH ; (nur ; die ; beiden ; Comments)
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    In:  Geophysics, Basel, Inst. f. Geophys., Ruhr-Univ. Bochum, vol. 50, no. 7, pp. 1091-1099, pp. L14310, (ISSN: 1340-4202)
    Publication Date: 1985
    Keywords: seismic Migration ; Spatial resolution
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 33 (1985), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Notes: In dealing with the problem of large amplitude multiple reflections arising from a hard water-bottom, it has been found that the use of extended source array techniques resulted in a considerably better penetration than that obtained using either computer simulated long arrays or the conventional air-gun array systems. The purpose of this paper is to use the concept of the array directivity factor in discussing the reason for the improvement in penetration achieved by using extended marine source arrays.Examples are given showing that the low frequency power radiated within the so called “penetration window” can be increased by a factor of two by choosing the correct spacing of the point sources forming the extended array. It is concluded that to ensure that most of the low frequency energy is concentrated within the penetration window to achieve deep penetration, a source array with spacing comparable with the wavelength is required.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 33 (1985), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 31 (1983), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Notes: Recently the author developed and demonstrated (Safar 1980) an efficient method for operating the airgun. The method involves the generation of a short seismic pulse from the pressure bubble pulses radiated by an airgun when fired several times at the same optimum depth but with different chamber pressures.The purpose of this paper is to present and discuss the test results obtained when implementing the same method using a two-dimensional airgun array. The array consists of seven 0.65 liter airguns fired simultaneously at the same depth but with different chamber pressures.It is shown that the far-field pressure pulse radiated by the seven 0.65 liter airgun array is similar to that radiated by the Flexichoc seismic source. It is concluded that the proposed airgun array can be used as a subarray to form an extremely powerful super-long array suitable for deep seismic exploration.The author would like to thank the Chairman and Board of Directors of the British Petroleum Co. Ltd for permission to publish this paper. Thanks are also due to Mike Symes and Lovell Cox for carrying out the field tests and Seismograph Service (England) Ltd for providing the airguns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 24 (1976), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Notes: A theoretical model is developed for predicting three important parameters of the pressure pulse radiated by an air-gun, namely the rise time, the amplitude of the initial pulse, and the period of the bubble pulse. A knowledge of these three parameters is essential for the efficient design of air-guns arrays.The prediction of the amplitude of the initial pulse is based on the assumption that the initial pulse is radiated by a spherical source with surface area equal to that of the air-gun ports and not by a spherical source with initial volume equal to that of the air-gun chamber, as has been assumed previously.A simple equation is obtained for predicting the period of the bubble pulsation, taking into account the effect of the air-gun body, boundaries such as the sea-surface and seabed and the presence of a number of identical air-guns placed at the same depth and fired simultaneously.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 25 (1977), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 33 (1985), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Notes: A simple field method was proposed by the author in 1976 for measuring the absolute amplitude of the pressure pulse radiated by marine seismic sources which radiate a bubble pulse. The proposed method involves the recording of the near-field pressure signature radiated by the water gun using a wide-band hydrophone. The key feature of the proposed method is that a knowledge of the hydrophone sensitivity and its distance from the water gun are not required.It is shown that the absolute amplitudes of the pressure pulses radiated by the S80 and P400 water guns obtained using the proposed method are in agreement with those obtained using a Ref-Tek hydrophone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 26 (1978), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 32 (1984), S. 0 
    ISSN: 1365-2478
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Physics
    Notes: The use of very long streamers in marine seismic surveys makes the response offset dependent. Line equalization networks are used to balance this effect.In this paper the response of the transformerless streamer system driving a charge amplifier is analyzed. Examples are given for a seismic cable 2500 m long, showing that the delay and the reduction in amplitude of the streamer impulse response in the absence of leakage are of the order of 1 ms and 0.6 dB, respectively. This means that the line equalization network currently used with the transformerless streamer system is not needed. We have also demonstrated that the presence of leakage resistance across the hydrophone group render the sensitivity of the transformerless streamer system offset dependent.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...