ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 12 (1996), S. 243-249 
    ISSN: 1573-2614
    Keywords: Cardiac catheter ; cardiac function ; clinical pathology ; hemodynamics ; histopathology ; temperature ; thermodilution cardiac output
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract The safety of a new continuous cardiac output monitoring system, recently introduced by Baxter Healthcare Corporation's Edwards Critical-Care Division, was evaluated in normal sheep. The study compared the biocompatibility and safety of the Vigilance® CCO Monitoring System, which employs a continuous cardiac output (CCO) catheter with Baxter Edwards' standard Paceport™ pulmonary artery catheter. The CCO catheter, which monitors hemodynamic pressures and provides continuons measurement of cardiac output based on the thermodilution principle, contains a thermal filament that is powered and controlled by a unique cardiac output monitor. Parameters were measured periodically in conscious animals and complete necropsies were performed alter each study. Time Control, Paceport™, and four CCO groups were studied. Selected groups were studied for 3 days (acute), 7 days (subacute), and/or 4 weeks after 3 days of continuons use (recovery). Results showed no significant differences between the CCO and Paceport™ catheters in any of the parameters studied. On gross pathology, observations were similar. The only difference between catheters were microscopie findings of focal subendothelial or subendocardial changes correlated with areas that could have corne into contact with the CCO catheter. In acute groups, these changes consisted of a localized myofiber degeneration or necrosis, while in subacute and recovery groups, consisted only of fibrosis. None of the changes were clinically significant. Thus, the CCO catheter, used in conjunction with the Vigilance® CCO Monitoring System, appears to pose no additional risk over a standard Paceport™ catheter in normal sheep after continuons use for up to 7 days.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...