Publication Date:
2017-01-01
Description:
A bunch-by-bunch measurement system has been developed at Pohang Light Source II. The system consists of a four-channel button pick-up, 20 GHz sampling oscilloscope and an 800 MHz low-pass digital filter. Upon measuring a bunch-by-bunch spatio-temporal beam motion matrix over many turns, singular-value decomposition analysis is used to reveal the dominant coupled-bunch modes. The system can diagnose injection oscillations due to kicker errors and the effect of resistive-wall impedance that gives rise to instability during operation.
Print ISSN:
0909-0495
Electronic ISSN:
1600-5775
Topics:
Geosciences
,
Physics