ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    American Association for the Advancement of Science (AAAS)
    Publication Date: 1982-04-02
    Description: Autoradiography demonstrated prominent retrograde labeling of olivocerebellar climbing fiber neurons after injection of tritiated D-aspartate into the rat cerebellar cortex or deep nuclei. Mossy fiber systems originating in the brainstem and spinal cord remained unlabeled. Potassium ion-induced depolarization of cerebellar slices resulted in calcium ion-dependent release of endogenous L-aspartate, L-glutamate, gamma-aminobutyric acid, and glycine. A 26 percent decrease in aspartate release was observed after 3-acetylpyridine-induced destruction of the inferior olive, supporting the hypothesis that aspartate is a neurotransmitter in climbing fibers.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Wiklund, L -- Toggenburger, G -- Cuenod, M -- New York, N.Y. -- Science. 1982 Apr 2;216(4541):78-80.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/6121375" target="_blank"〉PubMed〈/a〉
    Keywords: Amino Acids/metabolism ; Animals ; Aspartic Acid/*metabolism ; Cerebellum/cytology/*metabolism ; Glutamates/metabolism ; Glutamic Acid ; Glycine/metabolism ; Neural Pathways/metabolism ; Neurotransmitter Agents/*metabolism ; Rats ; gamma-Aminobutyric Acid/metabolism
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 495 (1987), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 305 (1978), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 38 (1990), S. 259-263 
    ISSN: 1432-1041
    Keywords: tacrine ; amyotrophic lateral sclerosis ; postoperative sedation ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of 9-amino-1,2,3,4-tetrahydroacridine; tacrine, THA, was studied after intravenous administration and following the first and last oral doses of a seven week clinical trial involving 8 patients with amyotrophic lateral sclerosis, ALS. Two surgical patients given intravenous THA for reversal of postoperative sedation were also included. Plasma concentration of THA and in some cases the metabolite, 1-hydroxy-THA, were assayed using a selective and sensitive method with high performance liquid chromatography. After an intravenous dose of 30 mg THA, the plasma concentrations were fitted to a two-compartment model. Plasma clearance showed a threefold interindividual variation with a mean of 2.42 l·h−1. Volume of distribution, Vα varied 100–680 l with a mean of 349 l. The plasma half-lives of distribution and elimination were 1.8 and 98.2 min, respectively. Oral bioavailability showed large interindividual differences and ranged 6–36% in the four subjects studied. After seven weeks treatment with oral THA, plasma concentrations immediately prior to medication were below 10 ng/ml in three patients and above 100 ng/ml in two patients. At the same occasion the plasma metabolite concentrations considerably exceeded those of THA. THA medication was associated with side effects in the majority of the patients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 30 (1986), S. 567-574 
    ISSN: 1432-1041
    Keywords: morphine ; lung clearance ; pharmacokinetics ; physiological model ; diabetes mellitus ; postoperative state
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The influence of lung uptake and lung clearance on the disposition of morphine was studied in surgical patients. In the postoperative period morphine was given intravenously by a two-rate infusion regimen. Under steady-state conditions samples of mixed central venous blood (pulmonary artery) and peripheral arterial blood (radial artery) were taken simultaneously and at the same time cardiac output was measured. The concentration differences between venous and arterial blood were used to calculate the extraction ratio of morphine across the lung. In all patients there was marked pulmonary uptake, but the concentration differences in most of them were small under steady-state conditions. The extraction ratio (mean ±SD) across the lung was 0.06±0.10, implying insignificant lung clearance. However, in two patients, both with diabetes mellitus, there was a significant concentration gradient, indicating that the lung could contribute to the total body elimination of morphine. On the other hand, the total clearance was similar in diabetic and nondiabetic patients (1190 and 1150 ml/min, respectively), implying that pulmonary clearance would have no significant influence on the kinetics of morphine. A physiologically based pharmacokinetic model was used to describe the disposition of morphine in postoperative patients. The model allowed simulation of pulmonary diffusion, uptake and elimination and supported conclusions based on model-independent experimental data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 11 (1994), S. 99-103 
    ISSN: 1573-2614
    Keywords: oxygen tension ; conjunctival ; blood volume ; cerebral blood flow ; sympathetic nervous activity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract An investigation of the feasibility and validity of measurement of the conjunctival oxygen tension as a monitor of peripheral circulation, blood and extracellular fluid volume and cerebral circulation was carried out in 7 healthy volunteers and 5 unconscious critical care patients with proven total cerebral infarction. The healthy volunteers were subjected to changes in hydration achieved by the administration of furosemide and subsequent rehydration by administration of normal saline. Conjunctival oxygen tension was found to be a sensitive indicator of changes in the degree of hydration presumably by its ability to detect changes in peripheral circulation depending upon circulating blood and extracellular fluid volume. A drawback is that other stimuli of the sympatho-adrenergic system such as temperature and pain, interfere with measurement in the conscious volunteer. In patients with presumed total brain infarction the conjunctival PO2 cannot be used as a reliable monitor of cerebral blood flow because of varying perfusion of the palpebral conjunctiva from the external carotid artery in the occasional patient.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 8 (1992), S. 37-43 
    ISSN: 1573-2614
    Keywords: Monitoring: heart, respirations ; Measurement techniques: magnetic resonance imaging; infrared telemetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract A system for patient monitoring during magnetic resonance imaging (MRI) is described. The system is based on remote auscultation of heart sounds and respiratory sounds using specially developed pickup heads that are positioned on the precordium or at the nostrils and connected to microphones via polymer tubing. The microphones operate in a differential mode outside the strong magnetic field to reduce various sources of interference from the MRI equipment. After amplification, the signal is transmitted as infrared light to a small, battery-operated receiver and a headphone set. Thus, the patient can be simultaneously auscultated both inside and outside the shielded MRI room by infrared transmission through a metal mesh window. Bench tests of the system show that common mode acoustic noise is suppressed by approximately 30 dB in the frequency region of interest (100–1,000 Hz), and that polymer tubing having a diameter of approximately 2 mm can be used for efficient sound transmission. Recordings in situ show satisfactory detection of both heart sounds and respiratory sounds, although the signal is somewhat masked by noise during imaging. A clinical test incorporating 17 sedated or anesthetized patients was also performed. In all but four cases, the quality of the breath and heart sounds was regarded as acceptable or better.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 6 (1989), S. 37-43 
    ISSN: 1573-2614
    Keywords: conjunctival oxygen tension ; experimental ; monitoring ; non-invasive ; septicemia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Continuous non-invasive monitoring of conjunctival oxygen tension (PcjO2) versus ‘conventional’ invasive hemodynamic and oxygen transport variables was evaluated in a porcine model of septic shock induced by a continuous i.v. infusion of E.coli endotoxin over 2 hours. Seventeen pigs under ketamine anesthesia and breathing air spontaneously were investigated. PcjO2, which reflects local oxygen tension at tissue level, correlated significantly at baseline and throughout the septic course with mixed venous oxygen saturation and oxygen utilization coefficient. All these correlations were significant at the 1% level. The corresponding correlations between PcjO2 and cardiac output were significant at the 5% level. A finding of great importance was that changes in PcjO2 preceded major changes in the intermittently measured physiological variables such as SvO2 and cardiac output. We conclude that PcjO2 monitoring is a valuable non-invasive method and which can provide a continuous assessment of the hemodynamic and oxygenation status in experimental septic shock.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 1986-01-01
    Print ISSN: 0031-6970
    Electronic ISSN: 1432-1041
    Topics: Chemistry and Pharmacology , Medicine
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 1990-03-01
    Print ISSN: 0031-6970
    Electronic ISSN: 1432-1041
    Topics: Chemistry and Pharmacology , Medicine
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...