ISSN:
1588-2780
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
,
Energy, Environment Protection, Nuclear Power Engineering
Notes:
Abstract The application, the advantage and limits of neutron monitoring techniques, such as Hf-monitors, fissile material accumulation and concentration monitors are being discussed. The active neutron counting technique applied to emptied pulsed extraction columns containing Hf-sieve plates allows conclusive answers as to the position of the plates in the columns. Pu-accumulations on Hf-sieve plates in pulsed extraction columns can be estimated within a factor of two, whereby the detection limit is about equal to or less than 1 g Pu/plate. Fissile material concentration changes of 1.1 g/l can be detected in the case of235U in solution and of 0.4 Pu/l if a239Pu/240Pu ratio of 4 to 1 is assumed.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF02040503