ISSN:
1588-2780
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
,
Energy, Environment Protection, Nuclear Power Engineering
Notes:
Abstract Inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the assessment of urinary uranium excretion in non-exposed subjects. The sensitivity of the method is high enough to determine238U concentration in unprocessed urine in any subject. Data obtained so far show a significant increase of238U excretion with age and no differences between males and females.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF02063647
Permalink