ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 43 (1971), S. 1903-1905 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 207 (1965), S. 1293-1294 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] In recent work, Gillespie and Inglis2 have shown that, when a-keratins are compared, they differ greatly both in the amount and in the type of 'high-sulphur' proteins which they contain. These results, when combined with analytical data3 on the 'low-sulphur' proteins (Table 1), strongly suggest ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 1834-1838 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine einfache, rasche und genaue Mikrobestimmung des Schwefels wird beschrieben. Die Substanz wird mit Natriumperoxyd in einer Nickelbombe zerstört, die Lösung der Schmelze mit einem Kationenaustauscher behandelt und das Sulfat unmittelbar mit Bariumperchlorat nach der Methode vonFritz undYamamura titriert. Das Verfahren ist auch für die Bestimmung von Chlor anwendbar, so daß die gleichzeitige Bestimmung von Schwefel und Chlor möglich ist.
    Abstract: Résumé Description d'une méthode simple, rapide et précise, de microdosage du soufre. La substance est décomposée par le peroxyde de sodium dans une bombe de nickel, la solution du mélange fondu est traitée par un échangeur de cations et le sulfate traité directement par le perchlorate de baryum d'après la méthode deFritz etYamamura. Le procédé est également applicable au dosage du chlore d'où il résulte la possibilité de doser simultanément soufre et chlore.
    Notes: Summary A simple, rapid, precise microdetermination of sulphur is described. The substance is decomposed by sodium peroxide in a nickel bomb, the solution of the fused mixture is treated with a cation exchanger, and the sulphate is titrated directly with barium perchlorate according to the method ofFritz andYamamura. The procedure is also applicable to the determination of chlorine, hence simultaneous sulphur and chlorine determinations are possible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 46 (1958), S. 228-235 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Erfahrungen mit dem vonSchöniger, Lieb undEl Din Ibrahim beschriebenen Apparat für Acetyl- und C-Methyl-Bestimmungen bestätigten die von den Autoren angegebene einfache, rasche und quantitative Destillation der Essigsäure. Es wird gezeigt, daß 1-n methylalkoholische Natronlauge nicht so wirksam ist, wie bisher angenommen wurde, sondern daß 5-n Natronlauge in Methylalkohol (33%) ein für Acetylbestimmungen besser geeignetes Reagens ist. Im Gegensatz zu früheren Berichten über die Analyse acetylierter Kohlehydrate erwies sich die alkalimetrische Titration der jodometrischen überlegen. Bei Berücksichtigung des Blindwertes für die nichtacetylierte Substanz erhält man auch für Kohlehydrate richtige Acetylwerte.
    Abstract: Résumé L'auteur a expérimenté l'appareil deSchöniger, Lieb etEl Din Ibrahim pour la détermination des groupements acétylés et C-méthylés; il a confirmé qu'il permettait d'obtenir une distillation simple, rapide et quantitative de l'acide acétique. Il a montré que la solution méthanolique normale de soude n'est pas aussi efficace qu'on l'avait pensé jusqu'à ce jour et que la solution méthanolique 5N (33%) est plus efficace et plus universelle pour les déterminations des groupements acétylés. Contrairement à des comptes-rendus antérieurs relatifs à l'analyse d'hydrates de carbone acétylés, il a constaté que le titrage alcalimétrique était supérieur au titrage iodométrique; il a montré également que pour obtenir des résultats exacts de détermination des groupements acétylés dans les hydrates de carbone il faut tenir compte dans le calcul d'une valeur correcte de l'essai à blanc effectué sur la substance désacétylée.
    Notes: Summary Experience with theSchöniger, Lieb andEl Din Ibrahim apparatus for acetyl and C-methyl determinations has confirmed the authors' claims that it gives a simple, rapid and quantitative distillation of acetic acid. It is shown that the 1N methyl alcoholic sodium hydroxide reagent is not as effective as has been thought hitherto and that 5N sodium hydroxide in methyl alcohol (33 per cent) is a more effective and versatile reagent for acetyl determinations. Contrary to earlier reports in connection with the analysis of acetylated carbohydrates, the alkalimetric titration of acetic acid was found to be superior to the iodometric titration; and it is shown that accurate acetyl values are obtainable for carbohydrates if one includes in the calculation the correct blank value for the de-acetylated substance.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 934-943 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Der Anwendung der Parr-Bombe für die Halogen-Mikrobestimmung stehen zwei grundsätzliche Einwände entgegen, denen zufolge sie einerseits manchmal unzuverlässig ist, anderseits aber wegen der hohen Salzkonzentration vor allem genaue Chlorbestimmungen nur schwer zu erhalten sind. Das vorgeschlagene Verfahren vermeidet den erstgenannten Nachteil durch Anwendung schärferer Reaktionsbedingungen, den zweiten durch Anwendung von Kationen-Austauschern für die alkalische Lösung. Die Halogenionen werden in üblicher Art potentiometrisch mit 0,005-n Silbernitrat titriert, wobei eine Platin-Indikatorelektrode und eine QuecksilberQuecksilber(I) sulfat-Bezugselektrode verwendet werden. Bei der Bestimmung von Bromid und Jodid wurden keine Schwierigkeiten beobachtet, zumal die Elektroden nahe beim Endpunkt gegen Zugaben von 0,02-ml-Portionen der Silbernitratlösung sehr empfindlich sind, und zwar auch ohne vorherigen Ionen-Austausch; darin liegt gegenüber früheren ähnlichen Methoden ein Vorteil, der vermutlich auf der Anwendung geringerer Mengen Oxydationsmittel begründet ist, obgleich auch ein anderes Elektrodensystem in Anwendung kam und Platinschwarz zur leichteren Zerstörung des Natriumperoxyds herangezogen wurde. Die Methode ist einfach, rasch und für Serienbestimmungen geeignet.
    Abstract: Résumé L'emploi de la technique de la bombe de Parr pour le microdosage des halogènes comporte deux objections principales: elle manque quelque fois de sécurité et rend très difficile la détermination précise du chlore, en particulier, du fait de la haute concentration saline des solutions obtenues. La méthode proposée permet de pallier le premier inconvénient par la mise en oeuvre de conditions opératoires donnant lieu à une réaction plus énergique, tandis que le second est évité en appliquant la technique d'échange de cations à la solution alcaline. L'ion halogène est titré potentiométriquement par la méthode classique, à l'aide d'une solution de nitrate d'argent 0,005 N et en employant un système d'électrodes composé d'une électrode indicatrice en platine et d'une électrode de référence mercure-sulfate mercureux. La détermination des ions brome et chlore est effectuée sans difficulté car les électrodes sont très sensibles, à des additions de 0,02 ml de la solution de nitrate d'argent au voisinage du point final de titrage, même sans faire appel à une réaction d'échange: ce fait constitue une amélioration sur des méthodes similaires qui ont été publiées antérieurement; il résulte probablement de l'emploi d'une plus faible quantité de mélange oxydant bien qu'en outre le système d'électrodes soit différent et que la destruction du peroxyde de sodium soit favorisée par l'utilisation de noir de platine. La méthode est simple, rapide et convient aux déterminations en série.
    Notes: Summary The use of the Parr bomb procedure in micro halogen determinations has two principle objections in that it is sometimes unreliable, and precise chloride determinations in particular are very difficult to obtain due to the presence of a high concentration of salts in the solution. The method proposed overcomes the former by use of more vigorous reaction conditions, whilst the latter is avoided by application of cation exchange to the alkaline solution. The halide ion is titrated potentiometrically, in the normal manner, with 0.005 N silver nitrate solution and an electrode system consisting of a platinum indicator electrode and a mercurymercurous sulphate reference electrode. No difficulty was encountered in the determination of bromide and iodide ions, since the electrodes are very sensitive near the end point to 0.02-ml additions of the silver nitrate solution, even without an exchange reaction; this represents an improvement on similar methods previously reported and is probably due to the smaller amount of oxidation mixture taken, although the electrode system was different and platinum black was used to help destroy sodium peroxide. The method is simple, rapid and suitable for series determinations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 1488-1489 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein seinerzeit beschriebenes Verfahren zur Bestimmung von Halogen in organischen Verbindungen wurde modifiziert. Es ist in dieser Form für die Bestimmung von Chlor besser geeignet.
    Abstract: Résumé Modification d'une méthode antérieurement décrite pour le dosage des halogènes dans les composés organiques afin de la rendre plus appropriée au dosage du chlore.
    Notes: Summary A method previously described for the determination of halogen in organic compounds has been modified to make it more suitable for the determination of chlorine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 45 (1957), S. 677-688 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine verbesserte Methode zur Mikrobestimmung von Alkoxylgruppen beschrieben. Eine geringe Abänderung dieses Verfahrens eignet sieh zur Analyse von Flüssigkeiten, wie z. B. Anisol, die nach der normalen Arbeitsweise nicht analysiert werden können. Es zeigte sich, daß die Reaktion der Substanz mit siedender Jodwasserstoffsäure bei Gegenwart von Phenol gewöhnlich sehr rasch verläuft und mehr von der Konfiguration des Moleküls als von der Zahl der Alkoxylgruppen abhängt. Die Analyse von 9,10-Dimethoxy-1,2,5,6-dibenzanthracen und Dimethoxytriphenylendioxyd verlief einwandfrei, obwohl von beiden Substanzen angegeben wurde, daß sie negative Ergebnisse liefern. Auf die widersprechenden Literaturangaben über die Alkoxylbestimmung wird hingewiesen und gezeigt, daß ein rascher Gasstrom von größter Bedeutung für die Erzielung guter Resultate bei dieser Bestimmungsmethode ist.
    Abstract: Résumé Description d'une méthode améliorée de microdosage des groupes alcoxyles. On peut utiliser une modification simple de la méthode pour son application à des liquides tels que l'anisole qui ne peuvent être analysés par mise en oeuvre des modes opératoires normaux. L'auteur montre que la réaction de la substance avec l'acide iodhydrique en présence de phénol est habituellement très rapide à la température d'ébullition et dépend plus de la configuration de la molécule que du nombre de groupes alcoxyles présents. Les analyses du diméthoxy 9,10, dibenzanthracène 1,2,5,6 et du diméthoxytriphenylénedioxyde ont donné des résultats satisfaisants bien que la littérature indique qu'ils sont alors nuls. L'auteur remarque d'ailleurs les contradictions que l'on peut relever dans la littérature relativement au dosage des alcoxyles et montre qu'un courant gazeux rapide est un facteur des plus importants conditionnant l'obtention des meilleurs résultats.
    Notes: Summary An improved method for the microdetermination of alkoxyl groups is described. A simple modification of the method may be used for liquids such as anisole that cannot be analysed by the normal procedures. It is shown that the reaction of the substance with hydriodic acid in the presence of phenol is usually very fast at the boiling temperature, and depends on the configuration of the molecule rather than on the number of alkoxyl groups present. The analyses of 9,10-dimethoxy-1,2,5,6-dibenzanthracene and dimethoxytriphenylenedioxide were successful although both have been reported to give zero values. Attention is drawn to the conflicting reports that have appeared in the literature in connection with the alkoxyl determination, and it is shown that a fast rate of gas flow is most important if the best results are to be obtained from this determination.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 64 (1975), S. 553-559 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine handelsübliche Probeninjektionsspritze (von Hand zu bedienen) wurde mit dem Vernebelungsgerät eines Schlitzbrenners mit Vormischkamer eines Atomarabsorptionsspektrometers zum Zweck der Metallbestimmung in 50 bis 500 μl Probe verbunden. Für 500-μl-Proben ergab die statistische Auswertung einen Variationskoeffizienten von 1,7% für Ablesungen der Peak-Höhe mit einem Digitalgerät. Um reproduzierbare Ergebnisse mit 50-μl-Proben zu erhalten (Variationskoeffizient 4,3%), mußten die PeakHöhen mit einem Schreiber aufgezeichnet werden, der seinerseits mit einem Digitalablesgerät gekoppelt war.
    Notes: Summary A commercially available sample-injection valve (manual version) has been coupled to the nebulizer of a premixed laminar-flow burner on an atomic absorption spectrometer for metal analysis in volumes of 50–500μl. For 500-μl samples statistical analysis showed an overall coefficient of variation of 1.7% for readings from the peak height facility of a digital read-out unit. In order to obtain reproducible results with 50-μl samples (overall coefficient of variation of 4.3%) it was necessary to use the peak height data obtained from a pen-recorder connected to the digital read-out unit.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: S-Carboxymethyl (SCM) kerateine preparations from a range of keratins were fractionated by acid precipitation into low-sulfur (SCMKA) and high-sulfur (SCMKB) fractions. Amiono acid analyses and optical rotatory dispersion measurements on the SCMKA fractions from different keratins indicated that the proportion of α-helical material (30-64%) increased with increasing leucine and glutamic acid contents and decreased with increasing SCM-cysteine and proline contents. It is shown that these variations in α-helix contents are due mainly to differences in the conformations of the principal components of the SCMKA fractions, although there is also a smaller contribution arising from contamination with varying amounts of non helical components. The thiol + disulfide contents for the parent keratins were measured and compared with the SCM -cysteine contents of the solubilized fractions. In general the SCM-cysteine contents of the SCMKA fractions increased with increasing thiol + disulfide content of the parent keratin, but these values were not directly proportional. The extent of total supercontraction in 8M LiBr solution was measured for the parent keratins and shown to bear no significant relationship to their disulfide contents. From the extents of first-stage and total supercontractions the disulfide contents of the contractile structures in the fibers were calculated according to a model described previously and compared with the analytical values for the SCM -cysteine contents of the SCMKA and SCMKB fraction. Data for both fractions were consistent with the model in that they were in each case related to the calculated values by a constant factor. However, because of simplifying assumptions in the model, it was not possible to identity positively one or other of these protein fractions with the contractile elements in the fiber.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 1957-09-01
    Print ISSN: 0026-3672
    Electronic ISSN: 1436-5073
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...