Publication Date:
2013-08-31
Description:
Heat pipe performance can usually be improved by uniformly varying or grading wick permeability from end to end. A unique and cost effective method for grading the permeability of an axial groove heat pipe is described - selective chemical etching of the pipe casing. This method was developed and demonstrated on a proof-of-concept test article. The process improved the test article's performance by 50 percent. Further improvement is possible through the use of optimally etched grooves.
Keywords:
FLUID MECHANICS AND HEAT TRANSFER
Type:
NASA, Goddard Space Flight Center, 15th Space Simulation Conference: Support the Highway to Space Through Testing; p 397-408