Publication Date:
1948-02-01
Description:
A 400-ft tower with an anemometer and an aspirated thermohm at each 50-ft interval and a precision wind vane at each 100-ft interval with indicators and recorders in the office building is described. With a “surface” observation level the lapse rate, hence degree of stability, is continuously recorded at nine levels; the character of mixing and amount of dilution of waste stack gases are thereby known.