ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9304
    Keywords: cytotoxicity ; impression materials ; addition-type-silicones ; condensation-type-silicones ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Silicones for dental impression largely are used to record the geometry of hard and soft dental tissues. They are considered to be medical devices, and the assessment of cytotoxicity is a necessary step in the evaluation of their biocompatibility. Extracts of six addition-type and six condensation-type silicones have been tested with L929 cells according to the ISO 10993 - Part 5 standard. The cytotoxicity was evaluated by three different methods: neutral red uptake, propidium iodide (PI) staining, and amido black staining. According to the selected specific assay, contact between cells and material extracts was maintained for 24 h in the first series of experiments; then, considering that in vivo application of these materials is restricted to a few minutes, additional experiments were performed after 1 h of cell/extract contact. Analysis of the results showed that the addition-type silicones are nontoxic even when tested after prolonged exposure of the cells to the materials while the condensation-type silicones were cytotoxic at 24 h of incubation. Nevertheless, harm to the patient actually could be negligible, considering its very short time of exposure in vivo. This is supported by our finding that most are not toxic after 1 h. We suggest that the experimental conditions of cytotoxicity testing have to be relevant to the in vivo situation; accordingly, the time of exposure should be designed carefully. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 485-490, 1998.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: leukocytes ; adhesion molecules ; flow cytometry ; polyethylene terephthalate ; pyrolytic carbon ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Leukocyte activation is one test for the evaluation of blood-materials interaction. The expression of adhesion molecules analyzed by flow cytometry provides a simple method to evaluate leukocyte activation by biomaterials: any change in these molecules can be predictive of the inflammatory activity of the materials. In this study the contact between leukocytes and uncoated polyethylene terephthalate or pyrolytic carbon-coated polyethylene terephthalate (PET and PET-PC, respectively) was inspected by analyzing whether the expression of some adhesion molecules involved in leukocyte activation, namely LFA-1 (CD11a/CD18), Mac 1/CR3 (CD11b/CD18), and LECAM-1 (CD62L) can be modified. By flow cytometry expression of the adhesion molecules can be studied separately on lymphocytes and myeloid cells. The materials tested reduced the total numbers of both leukocytes and neutrophils, although not significantly. Neither PET nor PET-PC changed the expression of the adhesion molecules in lymphocytes: this suggests that no specific immune response is stimulated. On the contrary, statistically significant changes were observed for monocytes and granulocytes: the percentage of cells expressing Mac-1 and the density of such antigens on cell membranes increased while the percentage of LECAM-1 positive cells decreased. Similar changes were observed when the cells underwent the inflammatory stimulus provided by an in vitro challenge with bacterial endotoxin. Our results demonstrated that polyethylene terephthalate activates leukocytes by modifying the expression in neutrophils of the molecules involved in the early phase of the inflammatory response. Even after coating PET with pyrolytic carbon, the ability of this material to activate circulating leukocytes was maintained. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 549-553, 1998.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1998-01-01
    Print ISSN: 0142-9612
    Electronic ISSN: 1878-5905
    Topics: Biology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Medicine
    Published by Elsevier
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...