ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 16 (2000), S. 465-470 
    ISSN: 1573-2614
    Keywords: respiratory physiology ; simulation ; education
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract In recent years students have increasingly objected to laboratory exercises involving animal subjects. We have replaced the valuable animal experiments with demonstrations using a full-scale human patient simulator. In small groups first-year medical students observe realistic clinical situations such as opioid-induced hypoventilation, pneumothorax, and pulmonary edema. Students obtain information through physical examination, arterial blood gas analysis and chest radiography. They practice interventions such as providing supplemental oxygen and mask ventilation, monitor the results, and develop a basic differential diagnosis and treatment plan. We utilize the clinical context to review fundamental concepts of respiratory physiology including the alveolar air equation and oxyhemoglobin dissociation curve. The students give these laboratory exercises uniformly superior evaluations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 11 (1995), S. 394-395 
    ISSN: 1573-2614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-2614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract While conducting a case-based teaching session using a full-scale simulator, the authors discovered that placement of a unidirectional PEEP valve in the expiratory limb corrects the gas flow pattern, despite an exhalation valve failure.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-2614
    Keywords: pulse oximetry ; capnography ; monitoring ; critical incidents ; simulator ; anoxic oxygen supply ; pneumothorax ; pulmonary embolism ; malignant hyperthermia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Objective. Many studies (outcome, epidemiological) have tested the hypothesis that pulse oximetry and capnography affect the outcome of anesthetic care. Uncontrollable variables in clinical studies make it difficult to generate statistically conclusive data. In the present study, we eliminated the variability among patients and operative procedures by using a full-scale patient simulator. We tested the hypothesis that pulse oximetry and capnography shorten the time to diagnosis of critical incidents. Methods. A simulator was programmed to represent a patient undergoing medullary nailing of a fractured femur under general anesthesia and suffering either malignant hyperthermia, a pneumothorax, a pulmonary embolism or an anoxic oxygen supply. One hundred thirteen anesthesiologists were randomly assigned to one of two groups of equal size, one with access to pulse oximetry and capnography data and the other without. Each anesthesiologist was further randomized to one of the four critical incidents. Each anesthetic procedure was videotaped. The time to correct diagnosis was measured and analyzed. Results. Based on analysis of 91 of the subjects, time to diagnosis was significantly shorter (median of 432 s vs. 〉480 s) for the anoxic oxygen supply scenario (p = 0.019) with pulse oximetry and capnography than without. No statistical difference in time to diagnosis was obtained between groups for the other three critical incidents. Conclusions. Simulation may offer new approaches to the study of monitoring technology. However, the limitations of current simulators and the resources required to perform simulator-based research are impediments to wide-spread use of this tool.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 15 (1999), S. 287-293 
    ISSN: 1573-2614
    Keywords: Anesthesia: volatile anesthetics ; Anesthesia: waste ; Anesthesia: cost ; Anesthesia: monitor ; Anesthesia: fresh gas flow rate ; Education: anesthesiology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Objective. The increasing focus on health care costs requires that all physicians evaluate practice behaviors. The primary emphasis in anesthesia has been limiting the use of expensive medications and interventions. Reducing waste is another approach, and volatile anesthetics are an appropriate target in that simple reduction of fresh gas flow (FGF) rates is effective. A monitor that measures and displays the cost of wasted volatile anesthetic was developed and used to determine if real-time display of the cost would result in decreased FGF rates, which, in turn, would decrease wasted anesthetic. Methods. The waste gas monitor (WGM) measures flow rate at the anesthesia machine's scavenger port, integrates this with agent concentration, and displays the calculated cost, real-time, on a portable computer screen. The WGM equipment was attached to the anesthesia machine in the gynecologic surgery operating room (OR) and those cases performed under general endotracheal anesthesia and lasting longer than one hour were eligible for inclusion. First year anesthesiology residents assigned to the study OR as part of a non-specialty rotation, were the subjects of the study. For each resident, after data were collected from at least two eligible baseline cases (Baseline Phase, WGM not visible and resident unaware of its presence), the monitor was introduced and data collection continued for at least three more eligible cases (Visible Phase). Results. Nine residents were initially enrolled, but due to scheduling difficulties only five residents completed the protocol. Data from cases using the WGM demonstrated a 50% decrease (3.58 ± 1.34 l/min vs. 1.78 ± 0.51 l/min (p = 0.009)) in the scavenger flow rates, which resulted in a 48% ($5.28 ± 0.68 vs. $2.72 ± 0.80 (p = 0.002)) decrease in hourly cost of wasted volatile anesthetic. There was no difference between the Baseline and Visible phases with regard to use of nitrous oxide or intravenous anesthetic agents. Conclusions. The WGM decreased wasted volatile anesthetic by encouraging decreased FGF rates.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 15 (1999), S. 227-232 
    ISSN: 1573-2614
    Keywords: simulation ; problem-based learning
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Background. We developed a problem-based learning exercise with a full-scale human patient simulator to teach residents the emergency management and differential diagnosis of acute intraoperative hypotension. Methods.We developed the exercise through the following steps: clear definition of learning objectives, preparation of an appropriate case stem, development of clinically realistic scenarios to illustrate objectives, and an interactive instructor to stimulate discussion. Results. The exercise focused on the differential diagnosis of intraoperative hypotension, and the acute treatment of hypovolemia, cardiac tamponade, tension pneumothorax, and anaphylaxis. Conclusions. Exercises on a full-scale patient simulator are a natural extension of problem-based learning. Recent research in learning theory provides the rationale for this teaching modality's potential as a learning tool.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 12 (1996), S. 89-89 
    ISSN: 1573-2614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 13 (1997), S. 293-297 
    ISSN: 1573-2614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...